RE: Real world connection to a heat pump over modbus

Thanks for writing this topic. I jumped the gun, it seems, after reading Part 1 and bought a Dell Wyse 3040 which only has 2GB RAM and 8GB storage. Wi...

2 years ago
Reply
RE: Samsung 12kw cycling?

@lfranklin From your consumption graph, I am not sure if this is just for your heat pump or the house, but the cycles appear to be approximately 5 per...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

You are correct. There should be a cable from terminal B17 in the control kit (the large white metal box with all the electrics inside) that goes to t...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

I find the display quite helpful, especially if you expand the time scale using the sliders. The energy consumed and energy output figures are measure...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

I think that Freedom Heat Pumps, who will have supplied this Samsung always recommend two water pumps, even when a buffer tank is not present. The fol...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

A COP of 3.5 is pretty good in my opinion. I now have a similar system since my buffer tank was removed, but I also have had 2 Honeywell valves chang...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

I strongly suspect that we have the same installers. Does G L ring a bell? I think you were fortunate to escape from having the buffer tank fitted, as...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

Thanks for the photos, which show that you have a Sontex heat meter (see my photo) and flow meter. This looks as if it is connected to PassivLiving. I...

2 years ago
Reply
RE: Low flow rate on Samsung Gen6 12KW heat pump

Hi, I suspect that your system includes a buffer tank with flow separation. This means that your primary pump controls flow to the buffer tank and you...

2 years ago
Reply
RE: Advice / Experience Sought for controlling a Samsung Gen 6 ASHP

Thanks Ian. I am comfortable with coding, having customised my critical care unit's computerised information system. I'm sure that it would still be a...

2 years ago
Reply
Reply
RE: Advice / Experience Sought for controlling a Samsung Gen 6 ASHP

@jonbennell Hi Jon, it looks as if you and I have been on similar journeys. Perhaps G L installed yours as well. I was also hoping to use the wired co...