Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 31, 2026
@wintergreen here's what I have - apologies if it's too small to read. I was left two sheets by the installers - with completely different COP figures...
My Daikin wall programmer has a button that allows you to switch on or off the space heating independently of hot water; both are separately programma...
@editor I watched the video - looks a great piece of kit. We have the same size PV array as you (6.1kWp) I think. Our average daily solar sent to grid...
Hi – I have a 16kW Daikin HT ASHP – system details below – which we’ve been running since August 2020. We have a combination of UFH and radiators. The...
Around 3000kWh for heating and DHW from January 1st to April 12th - I'm in central Italy and our January was a lot colder than normal - minimum temps ...
Thanks @iancalderbank that looks like a better solution than trying to retrofit some limiter to the mixing valves - and of course, our taps in the bat...
Hi @transparent yes, that all makes sense. Building regs are as far as I can see a recommendation here in Italy as the project manager in charge of th...
Hi @transparent take the point yes - this is the unit we have on the showers at our place: The technical information here states that the max tem...
Hi @saf1973 thanks for the update, very sensible. I've previously used schedule heating for DHW but since I turned off our space heating last week, th...
@derek-m yes good point. The total volume of water used is ca. 50l, but since we have the handle probably 80% towards max, does that mean roughly we a...
Hi @derek-m that all makes sense, thanks. The sensor is 77cm down inside the 155cm high tank, so if its seeing a 7C drop in temp from a single shower,...
Per "1) If my understanding is correct using only schedule will mean that your heat pump only performs DHW heating during the scheduled periods, so yo...
- 26 Forums
- 2,618 Topics
- 61.1 K Posts
- 666 Online
- 6,994 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Renewables & Heat Pumps in the News
An article on funding for heat pumps in case anyone is ...
By Jeff , 50 minutes ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks @editor , @indevolt-uk Subject to any comments ...
By JamesPa , 9 hours ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 9 hours ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 13 hours ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 13 hours ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 14 hours ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 15 hours ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 17 hours ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 17 hours ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 23 hours ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 1 day ago
-
As I was reading this article Mars, I was thinking that...
By Toodles , 2 days ago
-
RE: Tell us about your Solar (PV) setup
Installed in May 2011: 16*Sharp 245 W monocrystalline p...
By txmartyn , 2 days ago
-
-
RE: Say hello and introduce yourself
That doesn't sound 'right' to me. The national Smart ...
By Transparent , 3 days ago
-
RE: Growatt battery disconnected
I doubt this will happen, but I will try and suggest it...
By Eliuccio , 3 days ago
-
Understood. That's why I decided from the outset on a ...
By JamesPa , 3 days ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
On the litigation, I would not go there and definitely ...
By Batpred , 3 days ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
I suppose if your pv inverter packs up, you have a plan...
By Batpred , 4 days ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
Firstly check you are using sound power not sound press...
By JamesPa , 4 days ago
-
That’s the solar up and running, I don’t think it’s the...
By David999 , 4 days ago
-
RE: Seeking ideas / information / commiseration - Pure Drive
I agree with @colinc that you can reuse some of it. A s...
By Batpred , 4 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Im trying me best to ignore orangeman, I figur...
By Papahuhu , 5 days ago


