Another frosty night. Woke to an average downstairs temp of 18.1 upstairs 18.0. it needs to do better than that. If it can’t do better than that b...
There is no obvious space for the LLH in our utility room. Perhaps that is why it wasn’t installed. I wonder if adding an external volumiser would be ...
Hello. So this will be our first full winter with the ASHP. It was installed around the 20th of January last winter and has been fine. One slight issu...
I think it’s safe to say it isn’t connected up. I’ve just looked at what the LLH itself should look like and seemingly I don’t have one. I’m pretty su...
Just went into the LLH parameters from Mike’s link. Mine was completely off. Now set to 3 and it also allowed for the LWT during defrost to be adjuste...
@mikefl hi Mike. Is this meaured in the same settings as you told me about the other day to measure the LWT and return temperature? Or configurable vi...
Woke to 17.5 to 18.5 throughout the house. Low of -6 overnight. have identified an issue though as the utility room was freezing and no feeling of ...
-3.5 outside now and indoor temps slowly rising, despite the defrost cycles every 45 mins.
Now it’s at -2 and LWT hanging tough at 37. Big difference. The defrost cycle seems to be for 5 mins every 45 mins and that’s why it’s not getting bac...
just back from a rare day at the office and checked the temps. OAT 1.0 LWT 52!!!! Return temp 47!!! Energy use zero difference from yeste...
Yeah it’s the defrost cycle that’s fecking me up for sure. A few parameter adjustments made and going to get it all to a higher base from above zero, ...
@mab interesting question.
- 21 Forums
- 1,966 Topics
- 42.7 K Posts
- 64 Online
- 2,279 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
So far, I'm happy with moving to Eon next. Not paid any...
By Andris , 5 minutes ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
Don't lose sight of the fact that at some point to opti...
By JamesPa , 5 minutes ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@cathoderay Ok, that's odd. The Baxi chap came yesterda...
By Cathyem1 , 40 minutes ago
-
RE: Split system and pipe lengths for air source heat pump installation
@johnmo got it. Thanks.
By nickmorgan , 47 minutes ago
-
Is that because the only people who will quote for 45C ...
By JamesPa , 2 hours ago
-
RE: Battery storage to run Heat Pump.
OVO already offer such a rate. Only for certain makes ...
By JamesPa , 3 hours ago
-
RE: Setback savings - fact or fiction?
And finally, the R version tidied up a bit and larger, ...
By cathodeRay , 5 hours ago
-
RE: Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
Hi @damonc, parameter 2015 is the maximum outdoor air t...
By AllyFish , 5 hours ago
-
RE: Ecodan ASHP - How to optimise my set up?
Thanks everyone for posting this, so much useful info t...
By Bamnio , 6 hours ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
I have the same pump and if I am operating it correctly...
By Broadsman , 7 hours ago
-
RE: Is it KISS or constant – weather compensation vs. set flow temperature?
@editor Will get back. Lots to try. Thanks to everyon...
By cliffhanger , 8 hours ago
-
RE: Towel rails. An unexpected final hurdle
I had a similar issue but convinced the installer to le...
By Pie_Eater , 19 hours ago
-
RE: What is the best strategy for operating a very oversized heat pump?
This whole discussion highlights just how much of a mes...
By Mars , 19 hours ago
-
RE: NIBE F2040 12 kW heat pump and 100 liter buffer tank
@cheshirejohn thanks for the update and for sharing. I’...
By Mars , 19 hours ago
-
RE: SolarPV tables / online calculator
We've only had our solar since last June, but so far fo...
By Old_Scientist , 22 hours ago
-
@robs useful thread! Thanks for sharing - Octopus are c...
By big_si , 22 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@jamespa Agreed. I think it’s a case of much over muchn...
By Mars , 1 day ago
-
RE: Heat Pump Sizing & Installation Costs
Perhaps useful to have installed date too? To get conte...
By Tim441 , 1 day ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 2 days ago
Latest Topics
-
Battery storage to run Heat Pump.
By Broadsman 8 hours ago
-
Heat Pump Sizing & Installation Costs
By Mars 1 day ago
-
SolarPV tables / online calculator
By MichelleC 2 days ago
-
Samsung Gen 7 R290 12kW is not behaving how I expected
By Joshua 2 days ago