Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

KevH
@kevh
Member
Trusted Member
Joined: Mar 29, 2025
Last seen: May 3, 2026
Topics: 0 / Replies: 62
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa Thanks for this...do you mean take the control knobs off the TRVs and replace with a decorators cap? In addition to virtually locking down t...

4 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@toodles Thanks for your advice. I am down to a quarter turn open on the three LSVs on the three upstairs rads, so maybe there is a little (a smidgeo...

4 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@andrewj Many thanks for taking the time to explain, it is much appreciated. I am learning so much through following your postings and your exchange...

4 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

Bearing in mind that Octopus can apparently monitor our every move in regards to the hub, I would be concerned about invalidating the warranty. &nbs...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

I have plotted myself that exact same chart, and have assumed that the FT levels off beyond the set points, which I think personally is a weakness in ...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

Ah, yes, so the effect is to shift the WCC towards the cold end by about 5c, so that at -10c OAT your FT is around 46c? Sounds interesting. As @and...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

This is very interesting and is something I was totally unaware of until now. If I understand correctly, you have adjusted the ends of the WCC which...

5 months ago
Reply
RE: Cosy home (?)

That's a similar sized house to mine, also fully insulated, which also loses about 0.4/0.5c per hour on average. I can only think that we lose heat ...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

This is disappointing. Surely the engineer who called would have known this before he got in his van. I can only assume that he was expecting to fin...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@andrewj Watching with interest. I think that your interpretation of your data makes sense, in that the cold weather end of the WC curve does appear ...

5 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamesPA TJ actually recommends the warm weather value should be +15c above target temperature so if you are aiming for indoor temp of 20c, then that ...

6 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa Yes, I now get that the 50c top end of the wc range is too high, though I I can still try dropping the setting back for 5 nights (55 to 50) a...

6 months ago