Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 19, 2026
I must admit with cheap rate overnight, I’m starting to abandon a 2c setback, some rooms take too long to recover. Still playing around trying to find...
Thanks, I'm away at the minute so cannot get to my HA flow temp graphs, but I have it it running on a more constant basis, and I get this feeling that...
Yes I am finding that running it long and low is the better outcome also more comfortable throughout. with regards the water pressure what’s the po...
If I take out what the water heating from the gas, then I would say yes the generated kw is about right from previous, I also have an EV and play with...
So according the design info, Heat Loss: 9.99kw @ -2c Target: 440% efficiency at 40oC max flow temperature. I’ve not been running nowhere ne...
@lucia your reply must have helped my data came back today 😀
@ectoplasmosis perfect this now makes total sense to me.
@ectoplasmosis so it constantly breaches that number and turns on. I do know if I switch to expanded then it adheres to that temperature. So I guess...
So this is it, what is my chosen set point, how does it get that? Considering the Room Temp Mod explanation and mine is set to Inactive. I...
If I am in inactive mode, then how or when does setback kick in? Timer mode lets you specify a time and a temperature but as inactive the temperatur...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 2,871 Online
- 7,218 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
Sorry that was a mistype. I meant 2A2A ie a2a with 2 o...
By JamesPa , 8 minutes ago
-
RE: Electricity price predictions
@rob-of-york sounds like a term that Heidegger would...
By Papahuhu , 34 minutes ago
-
RE: Why don't people choose heat pumps?
An excellent concise exposition of loss aversion: a 4% ...
By cathodeRay , 1 hour ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Agree but remember to retain your isp router as they wi...
By JamesPa , 2 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 10 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 11 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 14 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 18 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 4 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 6 days ago