Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 23, 2026
Topics: 27 / Replies: 5421
Reply
RE: My horrific Samsung heat pump installation and experience

I would agree that this is absolutely the best way, however OP seems to be reluctant to replumb anything, hence my suggested sequence above which come...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

A couple more thoughts. Instead of using the lockshields to balance the rads in the rooms where you have removed the TRVs, you could use the 'caps' ...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

I think you said you can switch the volumiser out. So here, at helicopter level, is an outline suggestion. Switch out the volumiser Take off...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

For what its worth I use libre office draw for almost everything. Once you get used to it it cant do most things I need. I use it on windows but of ...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

I seriously hope you don't mean what you say in the first sentence. If you do, no wonder the system doesn't work. Samsung is right, plumb it two pi...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Good work. I think if this were my system then I would take the following approach to the heat exchanger and buffer: Heat exchanger: First a...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

I cant remember exactly the temperature in May but I would doubt that there are many systems that do not cycle at that time of year, simply because th...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

I guess my comment was a little tongue in cheek, but I do believe that MCS are seen by Government and others as the mechanism by which standards are m...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

I and, I am sure others, understand and sympathise with your concerns. Perhaps misguidedly, I (and I am sure others) are trying collectively to pin d...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

Isn't this what MCS is supposed to do. Government, as I understand it, view them as the mechanism to ensure standards are maintained and they speak e...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

OK, so I presume that the comparisons are for comparable years/periods? Im also assuming this is averaged over the heating season not DHW only or on...

3 years ago
Reply
RE: My horrific Samsung heat pump installation and experience

@iantelescope are you able to measure the temp difference between the the flow to the Heat Exchanger from the HP and the flow from the heat exchanger ...

3 years ago