Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 21, 2026
Topics: 28 / Replies: 5524
Reply
RE: New to world of ASHPs: Ideal Logic Air Monobloc heat pump 8kW questions

Can I ask what triggered you to do this. Did it change the house temperature? (No implied criticism, just trying to find out a bit of the background...

2 years ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

Not much to discuss based on that, the experiment seems to match what one would expect from a bit of logic (Yay!)

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

My strong gut feel is that, if you bypass the pump in the secondary, turn the thermostat up to full, bypass the buffer, it will work. Basically the h...

2 years ago
Reply
RE: Water tank location – where can I put it?

Thats not directly relevant because you are comparing real time heating with stored hot water. Real time heating is dominated by the raw power you ca...

2 years ago
Reply
RE: Flow rate vs emitter 'openness', and CoP?

I guess that depends on where you measure it. If measured at the heat pump then the flow rate for any given heat transfer at any given deltaT (across...

2 years ago
Reply
RE: Water tank location – where can I put it?

Typically DHW tanks are cylindrical and ~1.4m high (or more) Is the loft a possibility? If not then with the relatively small space available you ...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

@transparent I dont disagree in principle but ... in the real world where time is money and the customer doesnt want to pay the latter existing ca...

2 years ago
Reply
RE: Ecodan 6kW - is it "cycling", or normal operation?

For what its worth I had exactly the same experience with my Vaillant heat pump and have settled on operating in pure WC mode. One of the challenges...

2 years ago
Reply
RE: Underfloor heating: Diagrams with COP 'per water flow'

I read the post you referenced and Im not wuite sure what the question you are trying to answer is. If its this "In summary, if I had the choice...

2 years ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

I think your argument is based on the relatively unusual case of a very low loss house with a large slab/UFH operating at a low flow temperature. The...

2 years ago
Reply
RE: Controversial opinions - pure weather compensation, buffer tank, heat loss, oversized heat pumps

Thats fair. Essentially all the controller needs to do is adjust target flow temperature (or possibly the WC curve so that the heat pump is left to a...

2 years ago