Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 20, 2026
Topics: 28 / Replies: 5524
Reply
RE: Setback savings - fact or fiction?

Potentially a significant finding though since the expectation from the physics is that energy use is proportional to the difference. However are the...

2 years ago
Reply
RE: Setback savings - fact or fiction?

I think @cathoderay is correct and it goes even further (unfortunately). Robust empirical evidence (from which we might draw general as opposed to sp...

2 years ago
Reply
RE: buffer/volumizer cupboard space eater, do i need one?

Thanks for raising this and more particularly enumerating the options in a way that I havent previously seen. It may take a few circuits of the buoy ...

2 years ago
Reply
RE: efficiency factor of heat pump brands

I dont doubt you are right. That said I did some calculations a few days ago of the ratio (for a Vaillant heat pump) between the theoretical max...

2 years ago
Reply
RE: Heat pump's integral circulator pump

I have recently been pondering, while trying to help another participant in the forum, why some heat pumps bother to modulate the water pump to mainta...

2 years ago
Reply
RE: advice on excessive shortcycling and overall efficiency

As you say should be straightforward, good luck with the work!

2 years ago
Reply
RE: advice on excessive shortcycling and overall efficiency

I forgot you had a LLH and secondary pump. Is the service technician who visited proposing to remove it or leave it and add a buffer tank/volumiser i...

2 years ago
Reply
RE: advice on excessive shortcycling and overall efficiency

Yes, just blank off the unused ports. As you have fancoils I would put the volumiser in the flow, not the return, it might just soften the experienc...

2 years ago
Reply
RE: Fujitsu Waterstage WOYG160LJL Air Source Heat Pump

No problem if you want to ask more questions but without a doubt leaving these things from time to time is a good idea. only by doing so do you get t...

2 years ago