The higher design temp in the bedroom isn't necessarily bad eg spare bedroom used as an office or hobby room where maybe 18 would be not as comfortabl...
Heat Geek came straight back to me and sorted it out as the proposal was still active on their books so I don't think you'll have a h issues @davesoa
The way I read the sensocomfort manual is the flow temperature on the curve only apply at a target indoor temp of 20. If you adjust this up or down th...
I went via the Heat Geek website and had the same T&Cs saying the fee was refundable. I'm yet to get the refund after declining my proposal which ...
Really glad to hear you're pleased with the installation - it sounds like you've done a good job wrangling Octopus to give you what you want!
Larger heat pumps, heated pools, steam rooms and hot tubs in top of a normal domestic load were examples that came up today. I had a three phase suppl...
I had a survey from UKPN as I was considering moving my supply (inside to outside) and we touched in three phase. The costs were not small for a 3m ...
Found this which may explain what is going on: I read that UKPN is still doing 100A fuses.
Have you checked for any extras on the Octopus side? For example I had to either get artex removed or lift floorboards for an alternative pipe route -...
When I queried Octopus on the buffer I was told it was installed as a volumiser on the return line. They specifically mentioned to help with defrosts....
@lucia ah sorry I wasn't clear, I meant with BGs price being higher than Octopus how much lower was that from say the price that upgrades.heatgeek.com...
@lucia in your position, given a second survey that confirms what you suspected about the heat loss and agrees with your own calculation I wouldn't ac...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 16 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
Looks like you have a 25L buffer vessel, so I'm guessin...
By Old_Scientist , 3 hours ago
-
@bontwoody you’re joking! This story gets worse and wor...
By Mars , 3 hours ago
-
RE: Samsung Heat Pump – Can't Activate TW2 Pipe Sensor (for Delta T Control)
If you do suggest you consider repurposing it as a 2 po...
By JamesPa , 4 hours ago
-
-
RE: Say hello and introduce yourself
Fully agree with @cathoderay. My journey took 2 years ...
By JamesPa , 6 hours ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@editor Agreed. There is another point to be made h...
By JamesPa , 14 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
Tim, Yes ChatGPT thought I could get another...
By Mike Patrick , 14 hours ago
-
RE: Enabling WiFi: Samsung ASHP on Smart Things App
No problem, @richdorm; glad it helps.
By Majordennisbloodnok , 16 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
If that makes you feel happier then go ahead, but it wo...
By JamesPa , 16 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
I do already have the same basic setup, all room influe...
By cathodeRay , 17 hours ago
-
RE: IVT Greenline high pressure switch and electrical cassette errors
OK. You dont say whether it is from the feeds to/from ...
By JamesPa , 17 hours ago
-
RE: How can I programme a setback for my Samsung Gen6 8kW heat pump?
Yes, and probably also Adia although the latter has a m...
By JamesPa , 1 day ago
-
@editor I am all in favour of provocati...
By GrahamF , 1 day ago
-
RE: How to Understand Wiring Up a Heat Pump
Morning, On top of what everyone else I would deffo loo...
By Grantmethestrength , 2 days ago
-
RE: Sizing a heat pump: Save me from my headache
Got the results back from the one we’re ...
By Mikeatthezoo , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Thanks Lucia. I'll set aside some time to go through th...
By Transparent , 3 days ago