Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@saz Hi Saz, It is always difficult problem solving from afar. So, if my understanding is correct, your UFH, radiators and pipework are not new...
@saz Hi Saz, The fact that your radiators were not getting hot at the top was because they had air inside, which your installer will have removed...
@saz Hi Saz, It sounds like you have air in your system. Your installer should have bled all the air from your system, but may not have done so...
@editor Hi Mars, An excellent video, though I'm afraid it did not fill me with confidence for the future. Virtually all the areas discussed were one...
@grahamh Hi Graham, I watched the RED video with interest and was pleased to see that the designer had been trying to minimise heat loss and maxi...
@glanmenai Hi, I noted in your earlier post that you are limited for space in your backyard. I assume that you are aware that ASHP's require as much...
@editor Hi Mars, As an Engineer I have always found it very important to use the correct terminology, so I feel it necessary to discourage your use ...
@mike-patrick Hi Mike, I forgot to mention that you may be able to get a system with a little more output, it all depends on the available roof s...
@mike-patrick Hi Mike, Let me first of all say that I am a firm believer in fully utilising solar energy to reduce energy consumption. Without wi...
@editor Hi Mars, It may be useful to ask the MCS CEO about Sam's case, she still has not received any form of help and the builder and Omnie keep cl...
@editor Hi Mars, When you say that you lowered the water flow temperature from 45C to 35C, did you just lower the setting, or did you enable weather...
@editor Hi Mars, I suspect that you will not see a vast change at the moment, since the heat demand is still quite low. Please explain what you de...
- 27 Forums
- 2,810 Topics
- 66.4 K Posts
- 2,599 Online
- 7,216 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Electricity price predictions
I wasnt sure where to post An interesting meeting ...
By Jeff , 8 hours ago
-
RE: Why don't people choose heat pumps?
Again, spot on. The problem is that we in the UK have d...
By cathodeRay , 8 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
I should say my points are simply raised to test the fo...
By Jeff , 9 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Agree with everything else. Personally I think the as...
By JamesPa , 16 hours ago
-
There's a company called Xlinks who are proposing just ...
By Transparent , 17 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 19 hours ago
-
RE: Octopussy cosy 6 experience
@paultheheating Unless things have changed more recentl...
By Toodles , 1 day ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 2 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 2 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 3 days ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@etchedpixels Agreed, just a thought for others. I am...
By Watcher , 3 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 4 days ago
-
Coming back on subject... A shortened version of the ...
By Transparent , 5 days ago