Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@cathoderay The 'make it slightly warmer' or 'make it slightly cooler' facility that you request is already available on most controllers when opera...
I suspect that the system would still work, but probably not as efficiently as if the pipes are installed further down. As Transparent pointed out, it...
It is not a GSHP, so there is very little chance of the pipework freezing underground. It is actually a heat exchanger to heat or cool the intake air ...
Hi Katie, As you have not yet resolved your problem, I suggest that we go through your system in a logical and systematic manner. I have attached a ...
If your system is full UFH, why would you have a design flow temperature of 50C? When you state that the 'flow temps on curve', do you mean weather ...
I am sorry to read that you have switched off your heat pump, I hope that you have adequate anti-freeze in your system. From your comments I must pres...
You may find something suitable on this website.
According to the manual the 'brine' (Water and Anti-freeze mixture) pipework should be installed 1.2 to 1.6 metres below ground, because the temperatu...
I very much doubt that this is showing heat demand, since it is allegedly going from 100% to 0% over a period of a few hours.
I have not looked in detail at a cascade system, since the necessity has only just arisen. I have attached a copy of the very comprehensive manual tha...
@ecodannewcastle Correctly adjusted weather compensation will vary the LWT automatically, rather than your present manual adjustment. Let me explain...
The problem with homes is that many of them will insist on being different, so that a 'one size fits all' heating system is not possible. Correct me ...
- 27 Forums
- 2,744 Topics
- 64.4 K Posts
- 799 Online
- 7,147 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Flushing system, cleaning and inhibitor
If an old radiator was reused, perhaps it was full of s...
By bobflux , 2 hours ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Such elegant symmetry. look at my lumpy bag of...
By Papahuhu , 4 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
This is very helpful, thank you.
By dansus , 10 hours ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 12 hours ago
-
I am surprised by Vaillant and I would press them on th...
By JamesPa , 12 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s Look forward to making contact soon! Regards, To...
By Toodles , 12 hours ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 1 day ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 2 days ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 2 days ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 2 days ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 4 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 5 days ago