Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 12, 2024
With all this talk about noise, I thought I would drop in a reference to a case where neighbours have (perhaps justifiably) complained about two ASHP ...
It sounds as if 3-phase supplies should be added when EV/solar/heat pumps are installed. It is unfortunate that such high energy items tend to be sing...
"That's not a heat pump, it is a circular gas boiler; the R32 gets re-used for about 15 years; it requires forced ventilation to prevent technical iss...
Does PD/planning permission apply to heat pumps fitted inside the house (for instance for integrated water cylinders and heat pumps)? I'm reminded of ...
I'm not entirely sure how 3x 3.6kW inverters will play out with respect to DNO permission ... I'm guessing you'd have to use the G100 certification an...
To be fair, I think our contexts differ, which pushes us towards favouring different solutions. Being a townie, having limited electrical engineering ...
Note that Sunsynk inverters are made by Deye but have some custom firmware and a sales agreement preventing Deye from selling in Europe South Africa a...
Are you totally sure you want to go down the off-grid inverter path? What loads will this support? Have you sized it to cope with peaks (e.g. machiner...
Good to hear that this is going forwards. At the risk of going off-topic, DIY-ing the batteries might be a good way to save some pennies. A 14.4k...
@ericdo I believe your outdoor unit is too large to meet Permitted Development, regardless of where it is sited. The LG HM121M.U33 is listed as being ...
Are you sure this proposed location has sufficient air-flow? Will it fall within 1m of the boundary (thus ruling itself out of permitted development)?...
I would hope that your heat pump commissioning pack would have much of this information, especially the design flow temperature (which is critical to ...
- 27 Forums
- 2,786 Topics
- 65.8 K Posts
- 3,125 Online
- 7,191 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Nook batteries from Octopus
just wondering if anyone has got any Nook to confirm wh...
By Batpred , 31 minutes ago
-
RE: Missing flow temperature in Heat Geek proposal
Of course we do not know for sure what the future will ...
By Batpred , 3 hours ago
-
RE: tepeo ZEB UK Support & Info Thread
There is at least one large scale system in this catego...
By Toodles , 6 hours ago
-
RE: Getting closer to a finished Haier system
Apart from sealing the external Primary Pro joints and ...
By Singlespeed , 11 hours ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
@jamespa Hope someone tries it! As a consumer, I woul...
By Batpred , 1 day ago
-
RE: Air-to-Air Heat Pumps & Air Conditioning: UK Heating and Cooling Q&A
Our latest Homeowners’ Q&A episode has just dropped...
By Mars , 1 day ago
-
RE: Vaillant ecoTEC Plus with sensoCOMFORT and weather compensation
Yes, its described in the sensocomfort manual. Its als...
By JamesPa , 1 day ago
-
RE: Heat Geek installations: share your experiences
My summary, highlighting the oddities.
By Batpred , 1 day ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
What a day yesterday! Two podcasts recorded, brilliant ...
By Mars , 2 days ago
-
RE: Tesla Powerwall (2) Calibration Cycles
@davesoa I’m rather a Luddite, but when I was running I...
By Papahuhu , 2 days ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
I too use AI when researching online. It's able to co...
By Transparent , 3 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
There is now a new Secretary of State for Energy Securi...
By Transparent , 3 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Looks like an impressive bit of kit. Just ...
By Batpred , 3 days ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
The idealist in me says pioneers in this space should b...
By Batpred , 3 days ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Ah, that makes sense when a combi is in place. The boil...
By Batpred , 4 days ago