RE: Testing new controls/monitoring for Midea Clone ASHP

Interesting to know- is that with UFH? Another slight frustration with homely was that it wouldn't let you alter the max and min flow temps and that i...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Regarding the warm end of the WC curve, are there any particular parameters that people would recommend? I had it set as 31 degrees C at 16, which is ...

4 months ago
Reply
RE: Seeking Help for In-Principle Quote to fix a botched heat pump installation by Heat Geek Installer

@drei Id be wary of the reference in quote 1 to reattach the radiator using suitable plasterboard fixings. Assuming it’s a fairly substantial radiator...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@grantmethestrength that looks really good albeit must profess to not fully understanding all of what you have said! I'd love to have the knowledge to...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Just come across this video on youtube We have all radiators/no UFH. It isn't clear whether this setting would be beneficial with rads when on oc...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@papahuhu quite normal to get a cop of high 4s in September. Nothing outstanding that homely is doing there. At the moment without homely ours is ab...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Thanks- interesting and useful observations and I did notice that the set LWT was pretty much the line of best fit, so to speak, through the oscillati...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

This is the sort of thing I mean. I've added the T1S value to my plotly graph:

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Hi all- does anyone know if "T1S" is midea language for the target outlet temperature? I have Climate Curve T1S Calculated Value 1 as what I believe t...

4 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@cathoderay yes there is the modbus register list at the end of the manual and that makes sense what you say about read and write, so those are the on...

4 months ago
Reply
RE: Heat Pump Damage on install - useable or dealbreaker?

I wouldn't personally say it's an excessive demand. It is significant even if it doesn't affect performance and I certainly wouldn't accept it either....

4 months ago