Reply
RE: Knock on effective of balancing radiators

@jamespa I found the valve authority video which is very helpful. We have Pegler Terrier valves, but I cannot find any info on what the valve aut...

1 week ago
Reply
RE: Knock on effective of balancing radiators

Thank you @old_scientist @jamespa @cathoderay   This is all very helpful information! I was starting to come to the conclusion tha...

1 week ago
Reply
RE: Rate the quality of your heat pump design and installation

@editor The re-wording is now much better, it removes the layman's view that the install/design/efficiency etc was perfect, which as we know is nig...

1 week ago
Reply
RE: Knock on effective of balancing radiators

I am still in discussions with the installer about installing FRVs. Had I known how accommodating they were I'd have done that before the LSVs were ...

1 week ago
Reply
RE: Knock on effective of balancing radiators

Thanks @old_scientist I was going to turn TRVs down until I got the result I am looking, but your suggestion to start form zero is a much better id...

1 week ago
Reply
RE: Knock on effective of balancing radiators

@jamespa Thankfully we'd already experienced chrome towel rails and the minimal output that comes from them and had already decided standard type 2...

1 week ago
Reply
RE: Rate the quality of your heat pump design and installation

When I saw the world flawless that immediately to me meant perfect. I was once told aiming for perfection is pretty much impossible, unachievable an...

1 week ago
Reply
RE: Knock on effective of balancing radiators

Thanks @jamespa Yes, I'd be leaving several radiators fully open with no TRVs (all the downstairs ones) and 2 bathrooms as want the most heat in th...

1 week ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

@batpred The Pace BMS also isn't the best with it's balancing algorithm, along with most other BMS manufacturers. Only JK seem to have a handle o...

2 weeks ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

@batpred I'd change your JK balance start voltage a little lower to give a it a chance to actually balance your cells.