Reply
RE: Say hello and introduce yourself

@london-trader the vrc700 will be set with an artificially high heat curve to allow the heatmiser stats to operate. the trick is to set heat mi...

3 years ago
Reply
RE: Smart TRV’s in Cabinets?

Tado offer smart TRVs with a room sensor... the smart TRVs are assigned to the room sensor, all components will need to be on a sub network formed by ...

3 years ago
Reply
RE: Energy poverty, climate change and sustainable lifestyles

MCS still allows you to use on-off thermostats which is creating issues in excess energy consumption. Agreed that that doesn’t have to change, if clie...

3 years ago
Reply
RE: Rate your air source heat pump installer

@transparent the reason this doesn’t happen is that those advising government have stakes in it not happening. BEIS does consult the industry extensiv...

3 years ago
Reply
RE: Rate your air source heat pump installer

@morgan @editor the industry is not fit for purpose as many are finding out. do people really think north european countries in the EU put up ...

3 years ago
Reply
RE: Rate your air source heat pump installer

@zoomuno you need to know it is not easy to get decent training, and even decent support. i rang vaillant for instructions about something they ...

3 years ago
Reply
RE: Rate your air source heat pump installer

@zoomuno being in the industry and understanding the way it’s run is also depressing.. buyers of heat pumps are not the only ones taken for a ride ...

3 years ago
Reply
RE: High air source heat pump running costs – Vaillant AroTherm Plus

@webcmg if the floor is screed with tiles the flow temp only needs to be 20-27c radiators do release heat at low flow temps but in your case no...

3 years ago
Reply
RE: High air source heat pump running costs – Vaillant AroTherm Plus

VR 71 and 70s are wiring centres to control circuit pumps and valves. Connection one of these to a sensor comfort reveals a whole lot more.

3 years ago
Reply
RE: High air source heat pump running costs – Vaillant AroTherm Plus

@webcmg normally on a buffer the hottest heat requirement is at the top for obvious reasons. so the floor should be at the bottom, radiators at ...

3 years ago
Reply
RE: High air source heat pump running costs – Vaillant AroTherm Plus

I’m a heating engineer and use these controls regularly Vrc700/720 should be in occupied space so it can measure room temperature usefully.it’s ...

3 years ago