@london-trader the vrc700 will be set with an artificially high heat curve to allow the heatmiser stats to operate. the trick is to set heat mi...
Tado offer smart TRVs with a room sensor... the smart TRVs are assigned to the room sensor, all components will need to be on a sub network formed by ...
MCS still allows you to use on-off thermostats which is creating issues in excess energy consumption. Agreed that that doesn’t have to change, if clie...
@transparent the reason this doesn’t happen is that those advising government have stakes in it not happening. BEIS does consult the industry extensiv...
@morgan @editor the industry is not fit for purpose as many are finding out. do people really think north european countries in the EU put up ...
@zoomuno you need to know it is not easy to get decent training, and even decent support. i rang vaillant for instructions about something they ...
@zoomuno being in the industry and understanding the way it’s run is also depressing.. buyers of heat pumps are not the only ones taken for a ride ...
@webcmg if the floor is screed with tiles the flow temp only needs to be 20-27c radiators do release heat at low flow temps but in your case no...
VR 71 and 70s are wiring centres to control circuit pumps and valves. Connection one of these to a sensor comfort reveals a whole lot more.
@webcmg normally on a buffer the hottest heat requirement is at the top for obvious reasons. so the floor should be at the bottom, radiators at ...
I’m a heating engineer and use these controls regularly Vrc700/720 should be in occupied space so it can measure room temperature usefully.it’s ...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 164 Online
- 5,868 Members
Podcast Picks
Latest Posts
-
No. 12kW is obviously the maximum heating capacity (at ...
By benson , 5 minutes ago
-
Thank you. That simultaneously answers my question abou...
By Transparent , 20 minutes ago
-
RE: Heating Turned Off but Radiators Still Warm
What do you mean by 'turned off' exactly. Same questio...
By JamesPa , 51 minutes ago
-
RE: Low Flow Rate Error - 8 kW Ideal Logic ASHP - Help!
@wh0am3ye - OK, starting to make sense, but it does mea...
By cathodeRay , 1 hour ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
My apologies @batpred I overlooked that you'd already I...
By Transparent , 2 hours ago
-
@editor fortunately we have a boiling water tap in the ...
By bontwoody , 11 hours ago
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@Fiona, I really don’t want to disappoint you, but I ha...
By Mars , 13 hours ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
@dgclimatecontrol, hard to disagree with that. “Zero di...
By Mars , 13 hours ago
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
@matban I would have to check the CIBSE guide as we hav...
By ASHP-BOBBA , 14 hours ago
-
RE: Ecodan Energy Monitoring Pack
Hi @carpenterstation Did you ever resolve the energ...
By CAMorgan , 15 hours ago
-
RE: is a home battery without an EV worth it?
I would find it difficult to justify a battery without ...
By Batpred , 15 hours ago
-
RE: What is the Heat Geek Guarantee?
Very useful post, one observation: I can see why instal...
By Batpred , 15 hours ago
-
RE: Widespread failure of insulation installation
And there are different kinds I guess. One fri...
By Batpred , 15 hours ago
-
RE: Octopus tariffs - a quick comparison
Great summary, @majordennisbloodnok! I'd take the ho...
By Batpred , 16 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@mike-patrick I'm no expert... but believe your ASHP is...
By Tim441 , 19 hours ago
-
RE: Renewables & Heat Pumps in the News
Good News from NESO released today which d...
By Transparent , 19 hours ago
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
I agree with your last last sentence, but for another r...
By JamesPa , 19 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Just wanted to share my experience with this kit, as I ...
By Batpred , 23 hours ago