the because the people who advise the government work for component manufacturers outside the U.K. so the interest is sales only, not responsible engi...
As a heating installer the current chaos was all predictable 15yrs ago when condensing boilers became mandatory in the U.K. Almost all boilers then an...
I’m an installer of weather compensation control systems for nearly 17yrs. What is important to understand is that it is room temperature that is crit...
the great british mind complicating things to justify policy makers existence. Really heat pumps should be installed as the manufacturing compan...
@witchcraft Don’t get me wrong correctly installed heat pumps are as good a heat source as any. thr technology is world class. Vaillant is an ex...
@saz yes big companies in the heating industry are run like Department of Social Security or What ever it’s called! they also know the in...
@editor it’s great people are beginning to appreciate why the heating industry is the way it is. Truly the rot starts from the head…policy and manufac...
what’s needed is engaged local installers independent or through a proper a company that forge mature relations with end users. But this model conflic...
the fixed flow temp was put in because you have an on-off thermostat somewhere. this needs to go microbore is probably fine too.. i have weather...
german standards have mandate out door sensors on all heat generators since 1985. They don’t use on-off controls to control a heat pump and other pump...
@saz you won’t, they are just there to move equipment like washing machines in fairness as an installer I can tell you that if the install follows ...
- 26 Forums
- 2,340 Topics
- 53 K Posts
- 451 Online
- 5,998 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Configuration issues with 10kW Midea R32 heat pump
Sorry that was a screenshot of @curlyKatie - mine has...
By SteveT , 19 minutes ago
-
RE: Setback savings - fact or fiction?
As long standing followers of this debate will know, th...
By cathodeRay , 2 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira vs OVO vs EON.Next vs Boxt
I get the impression that that comment "they don't comm...
By JamesPa , 4 hours ago
-
@majordennisbloodnok Just in case there are variations ...
By Toodles , 5 hours ago
-
RE: Latest NIBE model has known defect and no solution
@kings I’m glad I could help. NIBE are taking this very...
By Mars , 7 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@jamespa yes, I'm under no illusions but in some respec...
By AndrewJ , 7 hours ago
-
RE: Poll for Time of Use, tariffs, technology
@majordennisbloodnok thanks. Unfortunately i can't upd...
By Tim441 , 10 hours ago
-
RE: The good, the bad and the not that great – my heat pump installation
It will be interesting to hear how you get on. Until re...
By cathodeRay , 10 hours ago
-
RE: Electricity price predictions
It seems the end of cfd payments is in sight, even if a...
By Batpred , 12 hours ago
-
-
@pie_eater Yes, I installed Homely to a Daikin heat pum...
By gery , 1 day ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@davidalgarve Potentially stupid question, but are you ...
By Sheriff Fatman , 1 day ago
-
RE: What a Bad Heat Pump Installation Looks Like
Spot on, for relatively little money, an air of ready "...
By Batpred , 1 day ago
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
@trebor12345 Ok that makes more sense and leads is i...
By JamesPa , 1 day ago
-
-
RE: Home energy storage & battery register
Now the proud owner of: 4.1Kw peak Aiko Neostar solar...
By TechnoGeek , 2 days ago
-
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
Aira called me back today, but not sure we got to the a...
By ChandyKris , 2 days ago
-
RE: Experience with Mitsu Par 50/60 Wireless Controller
The 27°C request doesn't boost the weather compensation...
By Sheriff Fatman , 4 days ago