Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Feb 13, 2024
@derek-m mostly because that is what the documentation that came with the heat pump says, and I quote "... and 30l/min on the 12 and 16kW unit." ...
I am going to say that my maths is probably not correct here [earlier post that said 30x]. Will come back following some more thought. A quick look ...
Here is one spec sheet I found. They are not for my valves, but the below are two different sizes of the V8043. You can see the impact at my target ...
@scrchngwsl That is a good question, one I am trying to work out for myself. Ideally you need to know your target flow rate to start. This simple nu...
@heacol What I am learning is how to understand the numbers. There is a big difference between getting 8.6 m3per hour with a 1 bar pressure drop (whi...
@heacol Thanks for the link. I already have a Grundfos Magna 3 [25-100]. I think I have a dodgy manual flow meter as well (seems to go down to 22mm ...
@heacol I am trying to fix my flow rate. I can get 30 litres per second but with the [single] pump running @95% of capacity and using 106w and making...
@iancalderbank - you might be able to get a really quick and cheap solution up and running with a couple of $5 esp32's, some 1 wire sensors and toit. ...
@cathoderay Excellent thread and great start, thank you. Given the many different circumstances I would suggest anyone heading down this journey t...
@iancalderbank Hi Ian I would not follow my route unless you also want to also add a PWM to 0-10v converter since I was not aware of the PWM option du...
@derek-m I think I got this info from one of your other posts and will rectify this shortly, though will be a bit convoluted as I need a PWM to 0-10v ...
@cathoderay You are 100% correct, and I apologise for the concise nature of my post, did not want to get into too much detail in this thread and was t...
- 26 Forums
- 2,700 Topics
- 63.3 K Posts
- 606 Online
- 7,108 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Electricity price predictions
Hmm, I think the last 25 years may disagree with that s...
By Old_Scientist , 5 hours ago
-
RE: Electrification and Independent Hot Water Systems Request for Knowledge
Even if they were an air/air system would be a...
By EtchedPixels , 5 hours ago
-
RE: Can DNO change a G99 export allowance once approved?
If you try and revise it they can definitely offer you ...
By EtchedPixels , 5 hours ago
-
RE: Air to air bus grant installer anywhere
That’s very disappointment. Like nobody bothered to eve...
By Adrian , 12 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: GotGordon Manufacturer: Samsun...
By Gotgordon , 1 day ago
-
RE: Summer heat is becoming the new winter cold in the UK. What are you doing about it?
@ian33a I am not easy with sleep either unfortunately…....
By MK4 , 1 day ago
-
RE: Renewables uptake near you
In a village of under 40 houses...Conservation Area. I'...
By Tim441 , 2 days ago
-
RE: Home Alone with Home Assistant (previously A Beginner's Guide to ASHP Monitoring)
Great news, @bontwoody.
By Majordennisbloodnok , 2 days ago
-
Haier R290 Super Aqua Monobloc. Output capacity tables.
As I mentioned in my introduction post, I've been consi...
By Singlespeed , 2 days ago
-
RE: What is possible with FIT, SEG, Hate Pumps and Batteries?
Thank you, everyone, for your replies. Our FIT provid...
By ian33a , 2 days ago
-
@mk4 And of course, the panels are less productive due ...
By Toodles , 2 days ago
-
RE: GivEnergy inverter tripping due to over-voltage?
I'm trying to get clarity on exactly when the inverter ...
By Tim441 , 3 days ago
-
RE: Samsung Heat Pump – Can't Activate TW2 Pipe Sensor (for Delta T Control)
Autocorrupt seems to be working overtime.
By Majordennisbloodnok , 3 days ago
-
RE: Vehicle-to-Home with a Heat Pump: Is the Technology Ready and Which EV Should I Buy?
I looked into that wallbox a bit more off the back of t...
By Majordennisbloodnok , 4 days ago