Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

william1066
@william1066
Member
Estimable Member
Joined: Jan 5, 2023
Last seen: Feb 13, 2024
Topics: 0 / Replies: 206
Reply
RE: 17kw Grant Aerona heat pump not performing

"leaving water temperature" aka flow. Regarding your second question TLDR response: Where the heat load @ -2 degC outside is < 100W [concrete/t...

3 years ago
Reply
RE: 17kw Grant Aerona heat pump not performing

I am in the process of doing it. Completed the bathroom (150mm spacing with 16mm pex al pex pipes) and the kitchen/dining (100mm spacing, topped with...

3 years ago
Reply
RE: 17kw Grant Aerona heat pump not performing

Definitely my experience when I had a brief test manually controlling the LWT I quickly went back to weather comp. I think best to do at @TomC is, us...

3 years ago
Reply
RE: 17kW Grant Aerona 3 - advice needed for pre-commissioning struggles

You should calculate 1.161 watt hours per deg C. So assuming you are going from 45-52 degC for all 300L using a 3kW element (no stratification) that...

3 years ago
Reply
RE: 17kW Grant Aerona 3 - advice needed for pre-commissioning struggles

I am facing the same challenge, how to optimise for efficiency. As per my posts on another thread, it seems, #1 - efficiency all comes down to one ...

3 years ago
Reply
RE: 17kW Grant Aerona 3 - advice needed for pre-commissioning struggles

I have been wondering about this myself. My night rate is almost 3x cheaper than my day rate (at the moment) and my cop day vs night likely to be les...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@sunandair > how do you know pump speed cannot be controlled? Yes my HP can control the pump, but I did not know that at the time as I was foll...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@derek-m I am back on this topic. So I looked at Grahams post on the carnot cycle, and some other stuff. And flow rate does not come into the effici...

3 years ago
Reply
RE: Our Grant Aerona R32 13kW ASHP installation

@bretix I think having aluminum i the circuit mixed with steel and copper means you need to be more on top of the PH of the circulating water as this ...

3 years ago
Reply
RE: Our Grant Aerona R32 13kW ASHP installation

@marvinator80 regarding -10 and ASHP - I have been told, that you need to take the "long view" and look over the whole year. This probably works bett...

3 years ago
Reply
RE: The dreaded fast "cycling"

@derek-m This is what I got when I tried to "fiddle" with the system and manually control the LWT, heat pump was very unhappy, I very quickly switched...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

Decided to check the specs of one of my Zone valves vs ESBE @ 45 lpm - so about 4x At more modest flow rates there does not seem to be much diff...

3 years ago