Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Jun 16, 2026
Topics: 16 / Replies: 3246
Reply
RE: Solar Energy - No Thanks.

Thanks @toodles for delivering the full text. I'm getting most of the Derril Water story from elsewhere, but I'm missing the crucial source referenc...

5 days ago
Reply
RE: Surge Protection Devices

No. The shape of the waveform has no bearing on the decision to use an RCD.   BTW. I'm still unsure why you're making "DC Component" into a...

5 days ago
Reply
RE: Surge Protection Devices

Erm... I can interpret that question in more than one way, so I'm unsure of the angle you're taking. All Type-B RCDs and RCBOs will correctly trip i...

5 days ago
Reply
RE: GivEnergy inverter tripping due to over-voltage?

Thanks Tim. That SolarEdge data also shows voltages above 253v. But we don't know enough to tell what's happening. Eg Is the voltage falling aga...

5 days ago
Reply
RE: Surge Protection Devices

I don't believe it's in the Vaillant documentation. I can see no functional advantage in a heat-pump being supplied via an RCD. It's purely a prot...

5 days ago
Reply
RE: Surge Protection Devices

The additional profit being made the installers.

5 days ago
Reply
RE: Surge Protection Devices

The issue isn't DC leakage. Type-B RCDs and RCBOs will trip correctly despite the waveform having a DC component present. You need the contacts to...

5 days ago
Reply
RE: Plug and play solar. Thoughts?

I just read that article, @jamespa It seems the bodies are beginning to pile up...

6 days ago
Reply
RE: Surge Protection Devices

OP wrote: So I'd be interested to know where the feed to the new CU is supplied from...... and what size cable it has between the two units.

6 days ago
Reply
RE: Surge Protection Devices

Hager CDB540HP is a Residual Current Circuit Breaker. Here's the English text in the Installation Manual.It measures current which leaks to earth. ...

6 days ago
Reply
RE: Surge Protection Devices

I'm 90% certain that the device you have does not operate as over-current protection. The number of Amps stated on it are the rating of the contacts...

6 days ago
Reply
RE: Voice from the future.

There's usually a group of people on the beach at Dover who know what details can be used to populate option-fields in UK Government forms.

6 days ago