I foresee a new business opportunity. I can start a new company to survey rental homes and replace old light-fittings with an LED unit at £5000 each...
The usual type of underground cable with a metal 'outer' is Steel Wire Armoured.This has an external Polyethylene (or XPLE) layer outside of the steel...
I too think that the Solis earthing diagram is confusing. As I see it the situation is this... We commonly have circuits which are protected by an...
I think their response is genuine, and becoming increasingly common amongst DNOs...... with the possible exception of UKPN in SE England. DNO's also...
That might be the case. But I think we'd need a link to such an instruction before we can follow that up. I have provided an additional earth for ...
My apologies @jamespa - I read what you'd posted here and had assumed that you were querying the designation of TN-S on the certificate, and the ...
@papahuhu the build up of ICE is a widespread problem.There are consumers complaining from New York to Minnesota and Chicago. Greenlanders are equal...
No. That's uncommon. It goes back to the days when homes had a separate off-peak meter. As I wrote below my diagram, a separate isolat...
For your PME (TN-S) supply the earth to each property is provided via the neutral wire.Your house earth connects to the Neutral at the Service Fuse. ...
I haven't previously met the concept of the local grid being fully self-diagnostic. The DNO Engineers have a device they can attach to the wires whi...
Here's the Power Cut map from Cornwall at 23:00 last night The best strategy for adding a (diesel) generator is to connect it to a dedica...
- 26 Forums
- 2,417 Topics
- 54.8 K Posts
- 350 Online
- 6,096 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Recommended home battery inverters + regulatory matters - help requested
@transparent The default export limit of 3.68kW isn't a...
By Sheriff Fatman , 11 minutes ago
-
RE: Fan unit Making terrible noise HELP!!
@gutoffowc Oh no, sorry to hear that, are you in the Ke...
By ASHP-BOBBA , 60 minutes ago
-
RE: Ideal HP290 14kW ASHP - how to optimise
Thanks everyone so much for your replies and help. Last...
By cmartinbwmba , 1 hour ago
-
RE: Sunsynk Whole House Backup Issue
@sheriff-fatman - could you please re-post that in the ...
By Transparent , 1 hour ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
@robs Just to quickly fill in some of the gaps in the r...
By Sheriff Fatman , 2 hours ago
-
RE: Running my new Nibe ASHP efficiently
I didn't. I spent a while manually messing around with ...
By jamieheatpumpnew , 3 hours ago
-
Hi, I think I’m having some issues with my Ecodan as...
By Patch321 , 4 hours ago
-
RE: I’m glad the cold spell is over!
I comparison with the 65kWh used above yesterday was on...
By Judith , 4 hours ago
-
RE: New Daikin 11kW Altherma 3M install - is it working as it should?
@synthbuilder Further to the above…‘What a difference t...
By Toodles , 4 hours ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
I should think so, I thought that pretty much universal...
By JamesPa , 4 hours ago
-
RE: Setback savings - fact or fiction?
I'm also inclined to look into how a defrost is actuall...
By cathodeRay , 4 hours ago
-
MLCP (Multi-Layer Composite Pipe) for ASHP
@editor nope. The info you reported was sufficient for ...
By iotum , 15 hours ago
-
RE: Experience - New Build / Complete New Heating System
@vincro I would be surprised if it is much above 5 to 6...
By ASHP-BOBBA , 16 hours ago
-
RE: Post-Traumatic Heat Pump Stress Disorder
Yes bang on and maybe I can illustrate that by way of e...
By iotum , 18 hours ago
-
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
A big thank you to @jamespa for all his efforts online ...
By trebor12345 , 21 hours ago
-
RE: GSHP WOES! Midland based engineer recommendations?
@editor It is indeed for servicing. My current service ...
By Morgan , 22 hours ago
-
RE: Speedcomfort radiator fans
In case it helps Andrew Kuhne on openenergy monitor has...
By JamesPa , 23 hours ago