Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 26, 2026
@derek-m They wish to impress upon us that the fresh air is free (I’m not so sure about the ‘fresh’, especially after the latest UK government announc...
@derek-m Heating on the “never-never’? Regards, Toodles (Glad to be able to post again! (Sigh)
@crimson It really is looking more likely that the downstairs rads need a serious uprating now. Your heat pump has the capacity, your pipework will pr...
@hughf As it is a ‘Hard Task’ (and I don’t doubt it when I see what a failure my two installer companies staff have been!) it strikes me that someone ...
And what about the pipe runs ‘outside’, i.e. in utility spaces or unheated buildings? Are they all well insulated? Regards, Toodles.
Just thinking about the ground floor pipework, we had our pipe runs insulated with foam material that is split and slips over the pipes; I suspect tha...
@crimson Are the pipes in areas outside of your ‘living envelope’, in other words, any runs outside of your living spaces, utility area, outside plant...
@hughf When I was researching what, which, where, how and why for fitting an ASHP and ridding ourselves of a starting to fail gas boiler, I asked pote...
@crimson When the radiators downstairs are up-rated and the LWT is lowered, you will find the upstairs lockshield valves are a little less tricky to t...
@crimson The next stage might be to fit the larger radiators downstairs; this will have several benifits, not only will it heat downstairs more effici...
Thank you Derek, at least it is only a little ‘Devil’ then! Regards, Toodles.
I suspect that the image was subjected to some filesize reduction so here is a close up of the displays. Toodles.
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,007 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
Looks like not much change in electricity prices in the...
By ChandyKris , 1 hour ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 1 hour ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 2 hours ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 3 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
I think this calculation goes the other way. 3.54kW ga...
By JamesPa , 3 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 19 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 19 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 2 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 3 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 4 days ago