Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Tasos
@tasos
Member
Trusted Member
Joined: Nov 25, 2024
Last seen: Mar 20, 2026
Topics: 0 / Replies: 87
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@cathoderay For what is worth, it was recently pointed out to me, in a Greek heat pump forum, that certain high-end manufacturers, like Hitachi or Dai...

3 weeks ago
Reply
RE: Midea ASHP – how to set weather compensation

I think I am short of radiators, as I have not done any changes after switching to heat pump from oil burner. Or I am doing something else wrong. &n...

1 month ago
Reply
RE: Midea ASHP – how to set weather compensation

Yes, it does not cycle and I use a buffer, as shown in Midea's diagrams for 2 zones. To use LWT below 35, you could "fool" the system by defining UF...

1 month ago
Reply
RE: Midea ASHP – how to set weather compensation

I do actually, but I don't yet run it in an "unconventional" way. This is a latest plot of operation: I have switched to UFH mode to see what happ...

1 month ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Hi all. I have made some progress regarding cause of cycling. First thing I noticed, is that cycling is exaggerated when set LWT is less than 40 C....

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@benson My system is a "simple" one: no DHW, no defrosts, no decontamination. So it is rather easy to decipher control logic. Would it be possible to ...

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

Please excuse my persistence, but I am struggling to understand what triggers the pump on-off. I presume it is some internal check or external signal....

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@mosibi I confirm this and the value in my machine (R290) is 35. But this is for radiators, If you tell it you use UFH, it will get lower. In fact it ...

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@cathoderay How come water at 35 ish C flows through an IAT of 21 C and does not lose heat ? Is there a buffer or a secondary network with its own p...

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

@cathoderay If I can see correctly, there are periods on the graph where LWT equals RWT and during those periods the unit shuts. If this is the case, ...

2 months ago
Reply
RE: Testing new controls/monitoring for Midea Clone ASHP

I wonder why it is cycling ? I thought this should be avoided. Is some thermostat intervening ? Is the unit oversized ?  

2 months ago