Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 20, 2026
@cathoderay For what is worth, it was recently pointed out to me, in a Greek heat pump forum, that certain high-end manufacturers, like Hitachi or Dai...
I think I am short of radiators, as I have not done any changes after switching to heat pump from oil burner. Or I am doing something else wrong. &n...
Yes, it does not cycle and I use a buffer, as shown in Midea's diagrams for 2 zones. To use LWT below 35, you could "fool" the system by defining UF...
I do actually, but I don't yet run it in an "unconventional" way. This is a latest plot of operation: I have switched to UFH mode to see what happ...
Hi all. I have made some progress regarding cause of cycling. First thing I noticed, is that cycling is exaggerated when set LWT is less than 40 C....
@benson thanks a lot.
@benson My system is a "simple" one: no DHW, no defrosts, no decontamination. So it is rather easy to decipher control logic. Would it be possible to ...
Please excuse my persistence, but I am struggling to understand what triggers the pump on-off. I presume it is some internal check or external signal....
@mosibi I confirm this and the value in my machine (R290) is 35. But this is for radiators, If you tell it you use UFH, it will get lower. In fact it ...
@cathoderay How come water at 35 ish C flows through an IAT of 21 C and does not lose heat ? Is there a buffer or a secondary network with its own p...
@cathoderay If I can see correctly, there are periods on the graph where LWT equals RWT and during those periods the unit shuts. If this is the case, ...
I wonder why it is cycling ? I thought this should be avoided. Is some thermostat intervening ? Is the unit oversized ?
- 27 Forums
- 2,792 Topics
- 66 K Posts
- 3,200 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
I think Heat Geek have done an amazing job on their bra...
By Tomtheheatingengineer , 5 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
I have just had 3 heat loss surveys, one by heat geek o...
By David , 6 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
I think that's the key question. After all inverter uni...
By Prunus , 7 hours ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 8 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
A unit which uses water to transfer the heat/chill from...
By Temperature_Gradient , 8 hours ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 9 hours ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 9 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
Good plan. If you can get half hourly meter readings a...
By JamesPa , 14 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@editor Most certainly. The heat pump was an ideal s...
By Abernyte , 14 hours ago
-
Although regulations may well vary from country to coun...
By Majordennisbloodnok , 15 hours ago
-
RE: Does anyone have experience of a smart water meter?
Yep I caught our slow leak from a £100 bill rise 8)
By EtchedPixels , 15 hours ago
-
RE: Do You Need a Buffer Tank or Low Loss Header for Underfloor Heating in a Large Property?
@jamespa in some cases, failing the Turing test might b...
By GrahamF , 18 hours ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
@energystoragetech The heat capacity of some...
By JamesPa , 20 hours ago
-
RE: tepeo ZEB UK Support & Info Thread
Sorry you are correct, I was remembering figures from t...
By JamesPa , 1 day ago
Members Online
No online members at the moment



