Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 18, 2026
@derek-m It's interesting what you say. We didn't understand how Octopus deals with exports when we signed up. We signed up with them because they p...
@transparent The borehole pump is a Rovatti 4ES8 - it is a .75 kW, 2A 3-phase. The circulating pump that I mentioned, Grundfos, is single phase. We...
@heacol Sorry, I made a mistake. My husband told me that he doesn't use high pressure - he backflushes (we had valves installed for that purpose).
Hi Derek, That's an interesting idea that we haven't entertained, and might have entertained if we were at the initial stages again. The question of...
@heacol We have no extraction licence as our extraction is below 20 cubic metres per day (we have the calculations of how much we use for heating and ...
Very good. I just sent the Hythe group an email saying we want to participate in discussions - although it would be much better if you could get here!...
Very instructive - we have 100 solar panels and no storage capacity so will be very interested in these discussions! The drilling companies were bot...
You are brill! Didn't know I had a Building Control Application for the GSH system! I have the DNO and the electrical test certificate, the HW Commiss...
@transparent @transparent We have no idea about Building Control - we didn't know they should have been informed about the GSHP system installation a...
We thoroughly investigated filters that might be installed to remove the clay particles from the water before the pump and heat exchanger. Unfortunate...
We have an open loop system that involves a borehole pump, a buffer tank, a pipe run to a plant room, a variable speed pump, and a plate heat exchange...
@mjr If Vaillant didn't have these parts in Germany I would agree. But they are apparently widely available across the EU, with distributors often off...
- 27 Forums
- 2,758 Topics
- 64.9 K Posts
- 1,417 Online
- 7,162 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Where heat loss surveys seem to go against practical reality
I am amazed that there is not something out there to me...
By JamesPa , 3 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
@bobflux The hydraulic simulator is very interesting...
By Rob of York , 8 hours ago
-
RE: 7kW EV Charger Options Advice
Thanks. Yes, we have patchy 4G. The only option we had ...
By Rusty , 14 hours ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 1 day ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@batpred I suspect it will be more this year. I had 9 ...
By AndrewJ , 1 day ago
-
RE: Surface mount or bury primaries for heat pump installation?
@jamespa It's rusting 🙂
By tomasmcguinness , 1 day ago
-
RE: Glass lined Cylinder for private water supply
Thank you, once again, for your replies. Yes...
By ian33a , 1 day ago
-
It’s been out a few days and Amazon has already attache...
By Mars , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes, and this is another point I agree. We did find a f...
By Batpred , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
A very good point. In effect, the DHW pipework is an em...
By cathodeRay , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@tim441 Here are those same three month periods for 202...
By Toodles , 4 days ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
@transparent thank you for your reply above. As alway...
By Old_Scientist , 5 days ago
-
RE: Adventures in heat loss calculations
@rob-of-york — thanks for posting this, all very useful...
By cathodeRay , 6 days ago