Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Mar 18, 2026
@derek-m It's interesting what you say. We didn't understand how Octopus deals with exports when we signed up. We signed up with them because they p...
@transparent The borehole pump is a Rovatti 4ES8 - it is a .75 kW, 2A 3-phase. The circulating pump that I mentioned, Grundfos, is single phase. We...
@heacol Sorry, I made a mistake. My husband told me that he doesn't use high pressure - he backflushes (we had valves installed for that purpose).
Hi Derek, That's an interesting idea that we haven't entertained, and might have entertained if we were at the initial stages again. The question of...
@heacol We have no extraction licence as our extraction is below 20 cubic metres per day (we have the calculations of how much we use for heating and ...
Very good. I just sent the Hythe group an email saying we want to participate in discussions - although it would be much better if you could get here!...
Very instructive - we have 100 solar panels and no storage capacity so will be very interested in these discussions! The drilling companies were bot...
You are brill! Didn't know I had a Building Control Application for the GSH system! I have the DNO and the electrical test certificate, the HW Commiss...
@transparent @transparent We have no idea about Building Control - we didn't know they should have been informed about the GSHP system installation a...
We thoroughly investigated filters that might be installed to remove the clay particles from the water before the pump and heat exchanger. Unfortunate...
We have an open loop system that involves a borehole pump, a buffer tank, a pipe run to a plant room, a variable speed pump, and a plate heat exchange...
@mjr If Vaillant didn't have these parts in Germany I would agree. But they are apparently widely available across the EU, with distributors often off...
- 26 Forums
- 2,725 Topics
- 63.8 K Posts
- 1,050 Online
- 7,126 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Jokes and fun posts about heat pumps and renewables
@transparent I’ve heard that that is why American cars ...
By Toodles , 3 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Have either quote provided room by room heat loss calcu...
By Old_Scientist , 17 hours ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@old_scientist if you are going DIY then you may wan...
By Papahuhu , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
After a short while that was followed by the 'power war...
By JamesPa , 2 days ago
-
RE: Samsung heat pump - data cable issue
That's well done. Cable is the correct type (LIYCY = 2x...
By bobflux , 2 days ago
-
RE: Electricity price predictions
I agree, we will find out at the next budget whether th...
By Old_Scientist , 3 days ago
-
RE: Missing flow temperature in Heat Geek proposal
@editor I went through HG website, so should be ok for ...
By sttpd1917 , 3 days ago
-
Who did the Freedom Heat Pump cloud server and what did...
By Mars , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
Reading between the lines of what octopus are doing wit...
By JamesPa , 3 days ago
-
RE: Air to air bus grant installer anywhere
The through wall two hole ones have their place (listed...
By EtchedPixels , 3 days ago
-
I hope it goes ok, Hon can be hard to set up IF the sof...
By Graham Hendra , 3 days ago
-
@clockworks Hi, So there is a big difference between st...
By ASHP-BOBBA , 3 days ago
-
@editor wellvery comprehensive answer. I will get all i...
By Keithb , 3 days ago
-
RE: Advice on my Heat Pump Journey: Old Stone Built Detached Cottage
all good advice I will follow this up
By PaulC , 3 days ago
-
Heat of vaporization of water is 2.25 MJ/kg (0.625 kWh/...
By bobflux , 4 days ago