I am doing almost the same as you and also noticed that it always takes a few minutes before the state is set to "DHW" (e.g. 3-way-valve SV1 is flippe...
A bit of topic, but indeed chatgpt and other AI a-likes have this tendency. Imho at this point in time you should not trust the output and always veri...
@benson”Active State” reflects the current state of your heat pump. And indeed the state of the 3-way-valve SV1 is taken into account to get the state...
@benson I checked the last week of data and i must say that is pretty accurate in those days, where the Shelly measures for example 4.65, the heat pum...
The Shelly provide “Current” (amp), “Power” (watt) and “Voltage” (V) for the current state and “Total energy” (kWh) as a counter since the last reset....
I have two Shelly 1PM plus (discontinued and replaced by Shelly 1PM Gen3), which is working perfect, but if I have to start over I would have chosen t...
@benson I have to Shelly devices to measure the power usage of the indoor and outdoor unit and created virtual energy meters in Home Assistent for hea...
Thx, but Sven did the hardware development. My role (as his father) is that I am guilty of purchasing an Airwell (Midea clone) heat pump that left us/...
Hi, Sven is not able to update the heat pump controller remotely. The controller’s firmware can be updated using the OTA update method described onAno...
Hi from the Netherlands. I have a Airwell Wellea Split (Midea clone) 8 kW heat pump and with these lower temperatures it is pretty stable. From 10 d...
The project self is indeed ESPhome based, but how you connect a modbus interface or information about the modbus registers is of course generic, hopef...
On my GitHub page you will find info about the connection and modbus registers.
- 26 Forums
- 2,300 Topics
- 51.6 K Posts
- 432 Online
- 5,965 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: 10kw heat pump run in 24*7 data?
I'm guessing the sharp dips in FT are defrost cycles. ...
By JamesPa , 7 minutes ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Oh I know, am just raging, apologies. 2 years has worn...
By Crimson , 12 minutes ago
-
Why Millions of UK Homes Struggle With Heat Pumps
For years, we’ve heard a consistent refrain from homeow...
By Mars , 17 minutes ago
-
RE: Help me keep the faith with my air source heat pump installation
Mine is running on a 3B, albeit one with the official p...
By JamesPa , 36 minutes ago
-
RE: Electricity price predictions
That's not how the electricity wholesale market (Elexon...
By Transparent , 58 minutes ago
-
That can cause significant losses due to phase imbalanc...
By Transparent , 1 hour ago
-
RE: Here is my heat pump installation with questionable COP in Italy
Hi, and welcome to the forum. I cant quite u...
By JamesPa , 2 hours ago
-
RE: DHW heat loss through pumps.
@marzipan71 Morning, it looks as though it's a very muc...
By ngillam , 3 hours ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira
A very interesting episode, and it was good to hear a c...
By Sheriff Fatman , 10 hours ago
-
I signed up to Havenwise control on the day after the h...
By Sheriff Fatman , 12 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Very sound reasons imho. My current feel, albeit based...
By JamesPa , 14 hours ago
-
That's not always the case.Let's see what they say once...
By Transparent , 16 hours ago
-
Hello All Our solar system consisting of 2 x 6Kw inve...
By AlanB , 17 hours ago
-
RE: BUS grant voucher expires before install date
@bornagain That is what our installer is pr...
By Bash , 17 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
I'm not so sure. New gas boiler £10...
By Bash , 20 hours ago
-
RE: Renewables & Heat Pumps in the News
I thought an aircon doubling as a heat pump could do ou...
By Batpred , 21 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Just wanted to share some info for anyone facing challe...
By Batpred , 23 hours ago
-
Daikin Altherma HT Temperature Sensor Question - Caution: Mentions AI...
Hi All - first post for a while, hope you are all well,...
By Marzipan71 , 23 hours ago
-
RE: Do Heat Pumps need to start up at Full Power?
@steelbadger We have an LLH with secondary pump; the se...
By Toodles , 1 day ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@jamespa Yes, the OAT sensor is situated on the back pa...
By Toodles , 2 days ago