Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

mjr
@mjr
Member
Reputable Member
Joined: Feb 23, 2022
Last seen: Mar 18, 2024
Topics: 2 / Replies: 299
Reply
RE: Rate the quality of your heat pump design and installation

@jswhite actually, yours sounds like one of the few uses where a twin-pump solution might have made sense. A single pump causes you problems in that s...

3 years ago
Reply
RE: MCS Certified installer problem

They're nearly all registered, with their serial number, half the control gear is inside the building and, if you have the melcloud module in the cont...

3 years ago
Reply
RE: Vaillant 10kw ASHP installation. Installer issues

I think it depends where your pump is. Our condensation drainpipe froze over in the cold and the pump slowly dribbled water across the paving from und...

3 years ago
Reply
RE: Rate the quality of your heat pump design and installation

There's nothing about being a leaky old house that makes ASHP necessarily impossible: it just costs more both to buy (bigger unit needed) and operate ...

3 years ago
Reply
RE: AI Heating Controls & IoT

Ah, but it also "reads" the return water temperature is lower (say, RWT = LWT - 8), because the house has taken more heat out of it because the house ...

3 years ago
Reply
RE: ASHP at cold temperatures

I hope you put that in writing and wish you luck with getting a resolution.

3 years ago
Reply
RE: Mitsubishi Ecodan not good enough ?

Yeah, that's still going to mean that the room temperature sensor on it won't reflect the house temperature, so using "auto adaptation" and "room" mod...

3 years ago
Reply
RE: Mitsubishi Ecodan not good enough ?

You don't need them, but the problem is that you MAY need them. No, it shouldn't be like that.

3 years ago
Reply
RE: Mitsubishi Ecodan not good enough ?

Cool. Who says it must? The rubbish way the pipe passes through the wall is one of my outstanding complaints with my installer too! I bodged some inst...

3 years ago
Reply
RE: Mitsubishi Ecodan & Raspberry Pi automations

"Auto adaptation" is used when both the FTC6/5/maybe-others main controller is set to a room temperature and DIP switch SW1-8 in the big control box i...

3 years ago
Reply
RE: Cosy Octopus - New ASHP tarrif

Having looked into the source of it a while ago, and done experiments with operation time, that "received wisdom" seems to be a distortion of the advi...

3 years ago
Reply
RE: Ecodan with UFH flow temperature consuming 130kWh per day

It can be done from both, but it's far easier from the controller: put the system into flow mode (menu: Heating: left button until pic of a water drop...

3 years ago