Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 28, 2026
@cathoderay Lots of data here. Firstly I would start by reframing your question from 'why does my house take more energy to heat using ASHP tha...
@cathoderay Lots of data here. Firstly I would start by reframing your question from 'why does my house take more energy to heat using ASHP tha...
Completely agree here. However, reducing it to the basics which I think we know irrespective of assumptions about COP or the accuracy of data from th...
I had understood the figures provided by @cathoderay to be measured electricity consumption (8 ish MWh/year) which he had multiplied by an assumed CO...
According to the databook the minimum output of the Midea unit at LWT55 OAT 7C is 9kW. So its cycling much of the time even if the 12.6kW calculated ...
Its easily done, I had to edit my response to get everything right. Yes if you have 12kW heat loss at -2 then you will need to inject 12kWh into the ...
Its easily done, I had to edit my response to get everything right. Yes if you have 12kW heat loss at -2 then you will need to inject 12kWh into the ...
I assume that the vertical axis is kWh/week (ie energy consumed/delivered in any one week), consistent with the title, can you confirm. If so oil pea...
As I said it depends on what you are trying to calculate. If you are trying to calculate heating load (ie what the house needs) then degree-days are ...
Be careful not to confuse kW (power) and kWh (energy). 12.3kW is the (calculated) peak power demand at the design temperature. To get to kWh/year yo...
@cathoderay Thanks The first observation I would make is this: 1100l oil per year is 11.4MWh. Even if your oil is 100% efficient that would sug...
@derek-m Surely that depends on what you are trying to calculate. Degree days will tell you about demand (load) profile whatever the heating technolo...
- 27 Forums
- 2,806 Topics
- 66.3 K Posts
- 3,243 Online
- 7,209 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
JamesPa Thank you. Just need to check my understand...
By trebor12345 , 49 minutes ago
-
RE: Free app: run the immersion / heat pump from Growatt battery & solar surplus – no Home Assistant
Please bear in mind, everyone, that in order to use thi...
By Majordennisbloodnok , 3 hours ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis Thanks for posting this and Im so pleased you ...
By JamesPa , 5 hours ago
-
RE: I need help with Ecodan ASHP
@f1p It turns out there have been a solar panel install...
By Andris , 17 hours ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews your installer would be right to say that the...
By GrahamF , 17 hours ago
-
RE: Tradespeople on Their Phones: What’s Acceptable When They’re Working in Your Home?
Actually, that's a very important point. I've only ev...
By Majordennisbloodnok , 1 day ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders can I just add to @rob-of-york s comm...
By JamesPa , 1 day ago
-
RE: Aerotherm and weather compensation
These are likely inked. The basic explanation is tha...
By JamesPa , 1 day ago
-
RE: Electrical works for air to air heat pump
agree with above. I have not had extra costs added wh...
By Batpred , 1 day ago
-
Good to hear that you found a solution. Absolutely a...
By Batpred , 1 day ago
-
RE: Are there any comparisons of DHW heat stores around?
@sarahemmm I have done things the opposite way round I ...
By Toodles , 2 days ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
The BUS grant funding for 2026/27 will run out at the c...
By Rob of York , 3 days ago
-
-
RE: Say hello and introduce yourself
@e-a-west as the good Major said, welcome to the forums...
By Mars , 5 days ago