Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 23, 2026
Topics: 27 / Replies: 5421
Reply
RE: Vaillant Arotherm Plus Help needed

And gas boiler that operates weather compensation does exactly the same, for the simple reason that you need a higher flow temp for dhw than for space...

3 years ago
Reply
RE: ASPH Sizing Confusion

Yes mine also. It seems a sensible approach to me, much more sensible than making DT across each emitter the same in a system where the aim is to ope...

3 years ago
Reply
RE: ASPH Sizing Confusion

I completely agree. However DT can only change by a small amount (~5C) in a tolerably well adjusted setup and each degree it changes is equal to half...

3 years ago
Reply
RE: ASPH Sizing Confusion

I think because 6-8kW, which a 22mm pipe can deliver at a typical DT of 5, gives a sufficiently fast recovery time for many people and... 22mm gives...

3 years ago
Reply
RE: ASPH Sizing Confusion

Well exactly that. Much of the discussion above focussed on 'delta T' being in this case the difference between flow and return temperatures. But th...

3 years ago
Reply
RE: ASPH Sizing Confusion

I must say that the recent posts about buffers are most encouraging. When I first embarked on this journey it seemed almost heresy to suggest on a pu...

3 years ago
Reply
RE: ASPH Sizing Confusion

Because it's been done in a completely muddle headed way. The requirement for accessing a grant has been conflated with both planning and building re...

3 years ago
Reply
RE: ASPH Sizing Confusion

One of the many reasons I think that MCS should be taken entirely out of the regulatory loop. That which needs to be regulated should be regulated th...

3 years ago
Reply
RE: ASPH Sizing Confusion

@fazel @bontwoody Anyone who said central heating system design is easy lied, particularly in a retrofit situation where one of many often competing...

3 years ago
Reply
RE: ASPH Sizing Confusion

Like most on here I'm not a heatpump engineer either. My background is in physics and engineering with a recent diversion into local government. So ...

3 years ago
Reply
RE: ASPH Sizing Confusion

If sizing for 35C leads to rads of a tolerable size then in principle i agree ( although you can do both) However I'm not chasing what you suggest, i...

3 years ago
Reply
RE: ASPH Sizing Confusion

That's interesting data provided that a) in doing your calculations you adjusted the lwt in the case of a cycling pump so that the average power...

3 years ago