Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 23, 2026
Topics: 27 / Replies: 5421
Reply
RE: Do setbacks save energy without compromising comfort?

It uses all the one minute data positive and negative except if the diverter is set to dhw.. Energy for defrost comes from the house so should be and...

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

If I understand the graph correctly the 60min average energy out seems to be around 8kW. Is this right?

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

Thanks for the data. I have taken this and plotted various adjustments. Here are the key results. Each point is one noon-noon measurement. I ...

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

yes it has thanks. I was apparently logged in, but I logged out and logged back in and this magically appeared

3 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

Clearly its either undersized (which is unusual but possible) or badly set up. Installer needs to take responsibility unless someone else did the cal...

3 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

Are you sure that the problem with defrost cycling is not caused by the LLH? Two reasons: 1. The LLH will in all probability reduce the FT to t...

3 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

Its unlikely to help unless you have a specific problem which extra system volume is likely to fix (eg short cycling). And if you have got a problem ...

3 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

Sorry but that sort of says it all. On another forum that I dip into the Grant/Chofu unit gets a generally good review, although most seem to recomme...

3 years ago
Reply
RE: 2.06 COP on LG Therma V 12kW ASHP – no idea how to improve it

The setup is design specific and a starting point should be the design flow temp at the desing min temp, but I guess you dont have these (or they were...

3 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

Sounds to me like an instant 10% penalty in efficiency, or more, for little tangible gain. Unless its properly controlled there will be mixing, which...

3 years ago
Reply
RE: 2.06 COP on LG Therma V 12kW ASHP – no idea how to improve it

OK step by step. The bad news us that your installer is that clearly either ignorant about heat pumps or a cowboy or both. The good news is that you...

3 years ago
Reply
RE: 2.06 COP, no idea how to improve it

There have been some cold days recently so on those you would expect low cop. However operating at a fixed flow temp of 60C is sheer madness and will...

3 years ago