Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 22, 2026
I would be careful with that presumption. Minimum volume is at least in significant part about defrost, and what matters is the minimum volume availa...
It sounds rushed to me but also that it may not be possible to question the direction. I hope you are lucky! Since he has been doing it this way fo...
Caleffi speak in one of their tutorials about the benefits of a 3 pipe buffer. Someone else may have taken the trouble to understand it. As always ...
Sorry but fundamentally you have to. The rate at which energy is absorbed by the emitters is determined by the flow temperature and the pipe area ...
OK. I think your theory, if it applies at all, applies to a small minority of use cases. The vast majority of our housing stock doesn't have UFH an...
Yes, its the 'integral' term in a proportional - integral - differential' controller. Vaillant actually call it the 'energy integral', the units are ...
Vaillant have the same concept. Basically its the sum (actual FT - target FT) * Time. So if the actual FT is 30 and the target 35 and this remains t...
Understood. You suggest (I think) that your data shows that oversizing is positively beneficial to performance in your case. Have I understood tha...
Maybe best not to sound too clever, it might upset him. You might be better first to ask why he thinks you might need 2 pumps and then, if necessary,...
Although i agree that the evidence that oversizing causes performance problems is at best shaky (albeit there are some logical arguments why it might)...
Well that's not really a reason. If he had said "because the index circuit has a resistance that is too high for the water pump" that would be a rea...
A buffer tank will be a cylindrical tank other than your DHW tank, or could be attached to your DHW tank.
- 27 Forums
- 2,799 Topics
- 66.2 K Posts
- 2,416 Online
- 7,206 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
@toodles GIGO always stands! My Cosy 6, as you can...
By Watcher , 1 hour ago
-
RE: Indevolt Batteries UK Support & Info Thread
@editor Mystery solved to some extent. Need to selec...
By dansus , 3 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Interestingly we had an internet outage about a month a...
By Rob of York , 7 hours ago
-
RE: Double or Triple Glazed Windows?
Posted by: @singlespeed With 9 years repairing windo...
By Rob of York , 8 hours ago
-
@transparent we’re still running a secure version of PH...
By Mars , 11 hours ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
Much longer than that here. The heating isn't even on. ...
By bobflux , 1 day ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Obviously the weather is changeable but there's a defin...
By Singlespeed , 1 day ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@rob-of-york I must admit that when we had a Daikin hea...
By Toodles , 1 day ago
-
RE: Forum updates, announcements & issues
Get the Renewable Heating Hub heads-up on WhatsApp. I...
By Mars , 1 day ago
-
RE: Safety study for plug in batteries out to tender - looks like Q3 2027 at best before legal
@editor I pointed out to the one of the Fuse execs that...
By dansus , 1 day ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews As well as loft insulation, there are othe...
By Rob of York , 1 day ago
-
RE: BT cuts you off, Plusnet blames Openreach... welcome to “seamless” broadband switching
Both of which (in most cases) use Openreach for the las...
By JamesPa , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Yes, this is a swiss and german standard I believe, Vai...
By Batpred , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@editor FWIW my problem was resolved, eventually, after...
By BigFish , 2 days ago