Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Sep 21, 2026
Topics: 27 / Replies: 5416
Reply
RE: Is My Midea Heat Pump Inherently Defective?

I don't think you can say 'This is not how a heat pump is supposed to run'. SOFAIK there is nothing wrong with operating a fixed flow rate (and thus ...

2 years ago
Reply
RE: ASHP and how it should run and potential kw consumption?

abut 1.5 bar, but I dont think it matters much unless you have a very tall house (it merely needs to be sufficient to ensure that negative pressure do...

2 years ago
Reply
RE: ASHP and how it should run and potential kw consumption?

Those cops sounds pretty close to what I see (7kW house, 7kW Arotherm). My energy delivered is currently tracking fairly close to what my measured ga...

2 years ago
Reply
RE: Double heat pump for DHW?

And, as an added bonus, the bed sheets won't need to be changed quite so frequently!

2 years ago
Reply
RE: ASHP and how it should run and potential kw consumption?

Like any heating system the consumption will depend on outside temperature. At the design minimum temperature you need to deliver roughly twice as mu...

2 years ago
Reply
RE: Double heat pump for DHW?

An arrangement which recognises that this is a modern totally unnecessary extravagance? Or as @iaack suggests, waste water heat recovery Or just s...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

Pretty much I'm coming to that conclusion, TBH it was my hunch when I started this thread but I wanted (and still want) to see if anyone comes up with...

2 years ago
Reply
RE: Hitachi Yutaki M efficient operation

No idea because not sure what they refer to. What's the context and what are the units and factory defaults? Mostly I would say leave things at...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

Some manufacturers publish this data including (but not limited to) Midea, Mitsubishi, Vaillant. Its not always easy to find, Mideas is in a password...

2 years ago
Reply
RE: Best control strategies for heat pumps that are way oversized

We don't and they may well be overstated. Certainly there is a reduction in efficiency because the heat pump has to run at a higher ft, but this migh...

2 years ago