Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 27, 2026
Topics: 28 / Replies: 5534
Reply
RE: Where heat loss surveys seem to go against practical reality

Absolutely, due to a combination of genuine unknowns (eg air change rate, effect of thermal bridging and even uncertainty in U values of certain mater...

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

Our posts crossed and I have added some more explanation/clarification In answer to your comment - no you dont know where in the range it lies, and ...

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

Its not perfect but the world isnt perfect . If one were to set up a controlled experiment with comprehensive logging that would be better than any o...

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

Yes from first principles. The temperature profile in any given location is well known and fairly consistent (averaged over a season) from year to y...

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

To clarify - the generally accepted divisor for SE England is ~2900 which is scientifically derived from a degree day calculation based on the SE UK t...

2 months ago
Reply
RE: Next steps on my ASHP journey: Radiators and Pipework

Surely the drops to the radiators are in parallel not in series, so the index circuit for pressure drop calculations will be determined by the longest...

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

I have one Mitsubishi Ilife2-slim fancoil to solve a problem that otherwise would have required either a large K3 or a superlarge K2. Its really quit...

2 months ago
Reply
RE: Surface mount or bury primaries for heat pump installation?

@tomasmcguinness Has it changed colour between photos or is that just the evening light?

2 months ago
Reply
RE: Where heat loss surveys seem to go against practical reality

@ian33a Given the nature of your house I think you did well to get estimates that close. I have to agree with this sentiment: and also The...

2 months ago
Reply
RE: vaillant aurotherm - Using Heating

Mine does the same, but recordw is only about 6kWh/month. I assume its a combination of quiescent power consumption, some of the things it does reg...

2 months ago
Reply
RE: Missing flow temperature in Heat Geek proposal

I can imagine 'get outs' but doubt they will use them. Heat Geek do appear to be 'industry leading' in offering this guarantee, and everything we hea...

2 months ago
Reply
RE: Missing flow temperature in Heat Geek proposal

Quite probably, does the guarantee come with any definitions of terms   Quite possibly yes, albeit perhaps surprisingly. Here is a plot f...

2 months ago