But presumably leaving the clips, visible in the photo, in place this providing the opportunity for vibration transfer
Me too, but still some people look at me as if I'm mad. Whilst I do accept that I probably am in fact mad, I cant see how being happy to have a gre...
yes but they are presumably insulated over the clips (unless you removed the clips and refixed them before insulating) so are hard against the rafters...
So run it without a buffer and instead add a supplementary pump slaved to the primary if the head required is too much for the built in water pump. O...
That may be contributing to lower than expected SCOP. 1600l=16MWh =very roughly 6kW loss assuming you were previously heating your house. Running con...
We could I'm sure (mine for example, nothing special at all, but it works), but it will be drowned out by the noise from the poor systems (which may w...
As a mere consumer I wholeheartedly agree with both of these. The question is how? What, if anything, is being done and by who? What, if anyth...
Not a clue quite frankly, other that to disguise problems which otherwise might lead to call outs. It seems still to be endemic sadly. @editor has...
MCS:3.65 Reported by Vaillant: 3.96 (heating only); 3.89 (heating plus DHW). Vaillant 7kW, radiators, FT 44@-2, room temp ~20.5, open loop, no buffe...
I think, based on what others have said here, that the Daikin adjusts its water pump to get the required DT. Others have said that you are asked some...
I'm intrigued by this exercise, so far you haven't reported that it was necessary to do anything other than the obvious. If thats the case then its y...
Water pump will certainly make a hum (which could conceivably be carried by the pipes) but the description does sound more like the compressor. It's ...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 130 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
Yes, I did mean graduates, but not just in physics. Q...
By Transparent , 5 minutes ago
-
RE: New Fogstar 15.5kWh upright solution
Oops. What I meant is when the wind blows, and in case ...
By Batpred , 29 minutes ago
-
RE: Heat loss calculations and how they work in conjunction with heat pump sizing
Doing the plot from heat pump output gives 6.5-7kW also...
By JamesPa , 1 hour ago
-
RE: Heat Pump Installers: Competence, Illusion and the Hard Truth Homeowners Must Face
@editor We defiantly need to come up with a way a custo...
By ASHP-BOBBA , 3 hours ago
-
RE: Radiator sizing for heat pump installation by British Gas - are these correct?
You are spot on. I don't know TBH as I don't have ...
By JamesPa , 4 hours ago
-
RE: Ecodan Energy Monitoring Pack
Interesting. I tried very hard to monitor energy consum...
By Carpenterstation , 7 hours ago
-
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂
@editor Just had my first defrost of this season. ...
By Mike Patrick , 7 hours ago
-
RE: Renewables & Heat Pumps in the News
@batpred We run our aircon in the summer not just to ke...
By dgclimatecontrol , 8 hours ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
That will be producing significant losses due to phase ...
By Transparent , 24 hours ago
-
RE: Isolating the system for a planned power cut
When I said we'd need to know more about the RCD, MCB a...
By Transparent , 24 hours ago
-
Which tells us something (including possibly everything...
By cathodeRay , 1 day ago
-
RE: Flexi-Orb Heat Pump Scheme Update: Progress, Pilots and Why This Matters for Homeowners
Thanks for sharing. Sounds promising, ISO are indepe...
By Batpred , 1 day ago
-
RE: Specifying batteries, pv solar etc using ChatGPT
I have been positively surprised when I asked it to spe...
By Batpred , 1 day ago
-
Thank you. That simultaneously answers my question abou...
By Transparent , 1 day ago