Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
The values you calculated are the quantity of thermal energy that the heat emitters can supply to the rooms. To keep the IAT reasonably constant, it i...
Hi Chillybot, welcome to the forum. Don't despair, there are quite a number of very helpful people on the forum, who will hopefully guide you throug...
I have attached a radiator output calculator in a spreadsheet. The yellow highlighted cells are the ones that can be varied. If you know the flow an...
Sorry I should have made it clear. Most forum members now use the abbreviation IAT to denote Indoor Air Temperature. Bet you can't guess what OAT mean...
Yes, many of us prefer the IAT slightly warmer. One of the pleasures of growing older. 🙄 Of course increasing the IAT, increases the heat loss, whi...
What happened to the IAT when you raised the WC curve?
It is possibly electrical interference on the cable rather than affecting the thermistor. The controller will be measuring the OAT by passing an elect...
@walkers-heatpump I can't remember how many industrial control systems I have fine tuned over my 50+ years career, but when possible the first thing...
One thing that I would suggest is that you switch off AA mode for a while and optimise the WC curve, since my understanding is that in AA mode the con...
@fazel Thanks fazel, much appreciated. I suspect that the training manual is for industrial type units, since the smallest compressor of a twin co...
@ggw In addition to the suggestions by AllyFish, another reason could be electrical pickup from a nearby power cable, that is only live when the hea...
Welcome to the forum and thank you for the detailed report. I must admit that I was not aware of the Compressor On Guard Strategy, which I don't belie...
- 27 Forums
- 2,815 Topics
- 66.7 K Posts
- 2,070 Online
- 7,230 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Plug and play solar. Thoughts?
Impressions so far from the one I've installed are that...
By EtchedPixels , 1 hour ago
-
-
@batpred The Daikin temperature probe protrudes from th...
By Toodles , 4 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
@editor And as an occasional contributor, may I say wel...
By Toodles , 6 hours ago
-
RE: Should Households Who Can Afford It Pay More for Energy to Help Those Who Can't?
They don't have to try. Our entire system is d...
By EtchedPixels , 7 hours ago
-
RE: Why don't people choose heat pumps?
Fair enough. I guess I was thinking of pipes that run ...
By JamesPa , 7 hours ago
-
RE: How Can I Prove Coal Was My Main Heating Source Without Receipts?
Got excepted for the grant now so thanks for the replie...
By Chilli304 , 11 hours ago
-
Daikin Altherma 3 R F+W, room thermostat control, weath...
By JanHarley , 12 hours ago
-
RE: Buffer tank on a 2 x 14kw Ecodan system
Pretty much as I had guessed in my crude scaling from m...
By JamesPa , 15 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
Well you have a vibration generator running at some fre...
By bobflux , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@downfield Thats a decent rate, I’m shocked they hadn...
By Papahuhu , 2 days ago
-
RE: Adventures in heat loss calculations
@toodles thanks! So as suspected, around a doubling of ...
By SusannaSaunders , 2 days ago
-
Six books in three years and I think I’ve now covered j...
By Mars , 2 days ago
-
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey
@heymikey Well done in achieving as nearer a match acro...
By Toodles , 3 days ago