Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Derek M
@derek-m
Member
Illustrious Member
Joined: Mar 4, 2021
Last seen: Sep 19, 2024
Topics: 7 / Replies: 4403
Reply
RE: Mitsubishi Ecodan & MEL Cloud

Are your problems now resolved? Feedback is beneficial for other forum members.

3 years ago
Reply
RE: ASPH Sizing Confusion

Why is the IAT always missing from the graphs?

3 years ago
Reply
RE: Mitsubishi Ecodan & MEL Cloud

Look at the LED's on the pump controller, or post a close-up photo if you are not certain how to interpret their meaning.

3 years ago
Reply
RE: Mitsubishi Ecodan & MEL Cloud

Looking at the schematic, this is how I suspect your system will be operating at the moment, though please correct any incorrect assumption I may have...

3 years ago
Reply
RE: Mitsubishi Ecodan & MEL Cloud

@leftbacks Thank you for providing the detailed schematic and photo's. The only comment that I would make is that I think the ESBE valve is a 3-port...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

@cathoderay So the LWT calculated by the simulation will probably need to be increased by 7.5C, to accommodate the probable 5C temperature drop acro...

3 years ago
Reply
RE: Mitsubishi Ecodan & MEL Cloud

Since numerous people have tried to resolve the issues with your system and appear to have failed, I suggest that we go through your system step by st...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

@cathoderay One thing that I did not do on this spreadsheet is accommodate the LWT to RWT Delta T, which should increase the calculated LWT value by...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

@cathoderay The actual spreadsheet was created quite some time ago and is quite basic compared to some more recent ones. You are on the right trac...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

I found a mistake in the body of the table in cell J29, the value should be 5841 not 11616. Sorry about that, one of the pleasures of growing older. ...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

@cathoderay I suspect it may be the time delay as the heat emitters warm up. Once all the heat emitters have warmed up they will not be absorbing as...

3 years ago
Reply
RE: Real world connection to a heat pump over modbus

@cathoderay The Heating Demand value in cell C1 should be the calculated heat loss for your home at the specified OAT detailed in cell E1. Cell H1...

3 years ago