Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
I also struggle with some of LG's descriptions in the manual which I believe may have been written by some form of sadist. My interpretation would b...
I did look at swimming pool heat pumps some time ago, since like A2A heat pumps, they are much cheaper, probably because they don't qualify for the go...
@andyj LG apparently call Weather Compensation (WC) 'Seasonal auto temp.', see page 123 of attached manual. Correctly adjusting the WC is not a 5 ...
Since a heat pump is merely a device for producing thermal energy, I don't see any problem on the face of it. Obviously it would only work effectively...
I believe that a PWM capable water pump will default to maximum speed if the PWM signal is not present. You therefore probably have three choices, obt...
If the Indoor Air Temperature (IAT) is holding steady at 18C, then the Weather Compensation (WC) curve is set too low. Try increasing the WC setting u...
@kev-m Thanks Kev. I will hopefully have time tomorrow to run some tests.
@kev-m A couple of further questions. When do you heat DHW? How much other electrical energy do you use that may be adding to the heating?
@kev-m Thanks Kev, I don't seem to be able to locate the PM'd messages. What are the WC settings and do you have anti-freeze, and if so, at what c...
That is why I suggested an Uninterruptible Power Supply (UPS). Most critical system within an industrial system would normally have some form of UPS.
I remember you sending a post providing details about your system, but I don't seem to be able to find it. Would you mind posting the details again?
I suppose that it depends upon your maximum instantaneous load and how long a power cut or interruption may last. There are battery storage systems ...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 847 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 18 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
Sooooo, what did we do in the end? We approached three ...
By Penval , 19 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 24 hours ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 1 day ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 1 day ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 2 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 2 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 3 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 4 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 4 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 4 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 5 days ago