Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Derek M
@derek-m
Member
Illustrious Member
Joined: Mar 4, 2021
Last seen: Sep 19, 2024
Topics: 7 / Replies: 4403
Reply
RE: Optimising LG Therma V R32 using AI

I also struggle with some of LG's descriptions in the manual which I believe may have been written by some form of sadist. My interpretation would b...

3 years ago
Reply
RE: Swimming pool ASHP used for UFH?

I did look at swimming pool heat pumps some time ago, since like A2A heat pumps, they are much cheaper, probably because they don't qualify for the go...

3 years ago
Reply
RE: Optimising LG Therma V R32 using AI

@andyj LG apparently call Weather Compensation (WC) 'Seasonal auto temp.', see page 123 of attached manual. Correctly adjusting the WC is not a 5 ...

3 years ago
Reply
RE: Swimming pool ASHP used for UFH?

Since a heat pump is merely a device for producing thermal energy, I don't see any problem on the face of it. Obviously it would only work effectively...

3 years ago
Reply
RE: ASHP & Buffer Tanks

I believe that a PWM capable water pump will default to maximum speed if the PWM signal is not present. You therefore probably have three choices, obt...

3 years ago
Reply
RE: Optimising LG Therma V R32 using AI

If the Indoor Air Temperature (IAT) is holding steady at 18C, then the Weather Compensation (WC) curve is set too low. Try increasing the WC setting u...

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

@kev-m Thanks Kev. I will hopefully have time tomorrow to run some tests.

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

@kev-m A couple of further questions. When do you heat DHW? How much other electrical energy do you use that may be adding to the heating?

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

@kev-m Thanks Kev, I don't seem to be able to locate the PM'd messages. What are the WC settings and do you have anti-freeze, and if so, at what c...

3 years ago
Reply
RE: Mini power outages and the self healing grid

That is why I suggested an Uninterruptible Power Supply (UPS). Most critical system within an industrial system would normally have some form of UPS.

3 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

I remember you sending a post providing details about your system, but I don't seem to be able to find it. Would you mind posting the details again?

3 years ago
Reply
RE: Mini power outages and the self healing grid

I suppose that it depends upon your maximum instantaneous load and how long a power cut or interruption may last. There are battery storage systems ...

3 years ago