Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Derek M
@derek-m
Member
Illustrious Member
Joined: Mar 4, 2021
Last seen: Sep 19, 2024
Topics: 7 / Replies: 4403
Reply
RE: -5c this weekend – what's your heat pump strategy?

Have you considered running your heat pump from the mains supply, rather than the batteries, during the warmer part of the day when the heat pump shou...

4 years ago
Reply
RE: 14kW Midea ASHP in an old leaky building

Here is one method you could try if your thermostats have a schedule capability. Rather than trying to program a change in WC curve or WC offset, pr...

4 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

Below is my interpretation of the various settings. #4051 0 = water pump off 1 = water pump on - speed range 0 to 100% 2 = water pump on -...

4 years ago
Reply
RE: How to best configure my Mitsubishi heat pump to work effectively?

Would you care to post a photo of your schematic and details of your circulation pump?

4 years ago
Reply
RE: How to best configure my Mitsubishi heat pump to work effectively?

You have a Samsung ASHP, which does not have an internal water pump, hence the need for the PWM control signal, whether it is used or not, to control ...

4 years ago
Reply
RE: Daikin ASHP experiences as part of our Italian renovation project

@marzipan71 Hi Steve, Thank you very much for the update. It is always useful to get feedback, both good or bad, and it also helps other forum rea...

4 years ago
Reply
RE: How to best configure my Mitsubishi heat pump to work effectively?

As far as I am aware, the Ecodan has an internal water pump, the speed of which the controller varies to maintain the Delta T at the heat pump. If y...

4 years ago
Reply
RE: How to best configure my Mitsubishi heat pump to work effectively?

As you state it is a black box, so we don't know what is happening internally within the controller. I am used to industrial control systems, where on...

4 years ago
Reply
RE: Heat pump delta T too low - 2c

@benseb Partially closed radiator valves both lockshield and TRV's will restrict the flow around the system, and hence the water pump will need to w...

4 years ago
Reply
RE: 12kW Samsung gen 6 short cycling

Looking at the schematic on page 13 of the attached manual, the Teva_in reading would appear to be from sensor T/S#5. There would appear to be no temp...

4 years ago
Reply
RE: What's your current daily damage?

The amount of electrical energy used is dependent upon the overall heat loss and how efficient your system is operating, plus of course the none heat ...

4 years ago
Reply
RE: Samsung 12kw efficient running. The little tweaks.

When I am testing systems I initially take readings at many points, then reduce the number of points once I discover which are important and which are...

4 years ago