Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@cathoderay How do you keep your heat pump running but not your PC when you have a power cut?
The heat loss, and hence heat demand, will be greater overnight, which means that the heat pump is unlikely to be operating at minimum output. The cyc...
DeltaT basically means temperature difference, which in your case will be the DeltaT between the WOT and WIT (water in temperature) at your heat pump....
I'm afraid that if I had a heat loss of 16kW per hour, I would be concentrating much more effort on lowering my heat loss than meeting it.
Your heat pump, when it is operating, is producing more heat energy than that required to heat your home, so the Leaving Water Temperature (LWT) will ...
If your controller is set to operate in WC mode, then you would normally have a large '0' (zero) shown on the display, which indicates that there has ...
Do you have any room thermostats? If so then set them 2C higher than the desired room temperature.
Well that fills me with a great deal of confidence. 🙄
Could you please explain why a heat pump would require a supply of heat energy to get it started? Seem very strange to me. 🙄
The only thing that I would add is to balance your radiators and UFH, so that you are getting the correct amount of heat energy to each room, to repla...
@cathoderay I had a further look at the following message with these results. Decimal. 010d77910303231e323041231905371919053c223c14310080 ...
Where is your water pump connected at the moment? Photo's may be useful.
- 27 Forums
- 2,742 Topics
- 64.4 K Posts
- 1,003 Online
- 7,146 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
Depending on your flow temperature you should get a SCO...
By JamesPa , 59 minutes ago
-
RE: PV and battery long payback - sense check query
They can also obtain smart meter data with a w...
By EtchedPixels , 2 hours ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 2 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Not interested in a plug in device, or 800w. Just need ...
By dansus , 7 hours ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 13 hours ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 1 day ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 1 day ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 2 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 4 days ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Dont, just adjust the LSVs to get different temperature...
By JamesPa , 4 days ago
-
RE: Heat pump running costs – what has actually worked for you?
I installed the air source heat pump in January 2026, i...
By bobflux , 4 days ago
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Thats all interesting. DHW on my Vailant seems to respe...
By JamesPa , 4 days ago