Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@newhouse87 I would suggest that you check through all the settings within the controller, to see what, if anything, is being switched on.
If you know who installed the heat pump, then they should be able to provide the heat loss calculations.
Switching on WC may show some improvement in efficiency, but the settings need to be matched to the heat loss of your home. What are the WC settings a...
Looking at the scaling of the graph, it is obvious that the purple line produced from Midea data is using integers. The displayed value goes up and do...
@cathoderay My meaning was to apply the 240v and 10A in the different calculation methods to see if there are any differing results. The problem wit...
@cashback Oh interesting! I'd heard of MVHR with cooling, but not MVHR with heating. At the moment I'm seeing MVHR as an option if a new slab is not...
The problem facing CR and probably other heat pump owners, is how to you know when the heat pump is operating at optimal performance. The problem is...
@cathoderay I suppose one way to check the overall accuracy of the various calculation methods, would be to use specified data over different time p...
@iantelescope Are you operating your heat pump in Weather Compensation (WC) mode, and if so, what are the settings?
To maximise overall efficiency with a heat pump, it is necessary to operate with the lowest possible LWT. To be able to utilise a low LWT, it is nec...
@cashback There doesn't appear to be a great deal of data shown in your example, is your heat pump switched off, or the data collection not working?
@beagles Are you operating your heat pump on a fixed LWT or Weather Compensation (WC)?
- 27 Forums
- 2,740 Topics
- 64.3 K Posts
- 427 Online
- 7,144 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
See here: which suggests 25-27L per kW for very lo...
By Old_Scientist , 40 minutes ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Unfortunately the answer is Yes you will need a new FTC...
By F1p , 14 hours ago
-
RE: PV and battery long payback - sense check query
So if it helps I was recently quoted about 8 grand for ...
By EtchedPixels , 15 hours ago
-
RE: HomeTherma Is Live: A New Home-Energy Platform Built Around the Homeowner
Signed up!
By bobflux , 22 hours ago
-
RE: Electricity price predictions
In our case, we constrain the charging level etc using ...
By Batpred , 23 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
I had a quick look and they are a little vague. They ...
By BlizzardGreen , 2 days ago
-
RE: Has anyone seen this problem before? Huge anticycling times
Oh dear. Glad it was replaced. I have been mighty imp...
By JamesPa , 2 days ago
-
RE: Can I start an argument about buffer tanks please? 🙂
Dont, just adjust the LSVs to get different temperature...
By JamesPa , 2 days ago
-
RE: Heat pump running costs – what has actually worked for you?
I installed the air source heat pump in January 2026, i...
By bobflux , 3 days ago
-
RE: Grant Aerona Air to Water R290 6.5 kW - Quiet Mark and Silent Running
Thats all interesting. DHW on my Vailant seems to respe...
By JamesPa , 3 days ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: adrian Manufacturer: Appliandirect.co....
By Adrian , 5 days ago



