@soniks FYI we have all brand new pipework and its 28mm, we have the volumiser with the heat element in it and we are getting flow rate of 32 with rad...
We have a 1920's house with a new big extension. We externally insulated and rendered the existing house with 70mm celotex along with high quality mod...
there is a single pipe in which is primary from ASHP and a single return pipe ... primary circuit is on the right as you face the LLH .... secondary i...
First picture shows a symbol not in the manual (as far as I can tell) so wondering if this is the supplementary heating in defrost cycle. The next p...
Important was that box EP001 was wired and it turns off the master valve supporting DHW prioritisation (which it wasnt at first) ... this now works an...
FYI the Grant combined volumiser / low loss header in my system has an immersion. The immersion doesnt connect to EP001 and instead connects directly ...
For the last month I have taken daily meter readings, for my 17kw grant ASHP the least usage being 25th Dec with 37kw/h, the worst being yesterday at ...
As I dont have an electric car and averge less than 30% electric between 00:30 and 6:30 I decided to switch from Economy 7 to single tariff .... now I...
thanks Derek, we do have a LLH my understanding thats to provide hydraulic seperation of primary and secondary circuits and cope with having multiple ...
The TM1 was 45 degrees ... my understanding is this is the max flow temp at -4 degrees for the weather compensation ... I reduced to 40 to try and see...
Hi @derek-m From the original spreadsheet before the reneuvation project started This was based on heating flow temp of 50 degrees due to upstai...
Hi @AllyFish, thanks for the detailed reply, ... I had no idea of the defrost details .... answers follow "17kW ASHP. Who sized it & on what...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 19 Online
- 5,868 Members
Podcast Picks
Latest Posts
-
RE: Renewables & Heat Pumps in the News
@transparent thanks I’ve learned a lot from your post a...
By Judith , 7 hours ago
-
@ashp-bobba Thanks. I'll be interested to find out why ...
By bontwoody , 7 hours ago
-
RE: Bizarre Retro-fixes by AAC
@editor So the risk was an uncontrolled electrical elem...
By ASHP-BOBBA , 8 hours ago
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
The ACH can actually make a huge difference. My heat l...
By Matban , 9 hours ago
-
Can that be interrogated using Modbus? Over an RS485 ...
By Transparent , 11 hours ago
-
If you've never played (or heard of) Pirate Fluxx, then...
By Transparent , 11 hours ago
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
Doesn't the Joule preplumbed cylinder include a buffer?
By JamesPa , 12 hours ago
-
RE: Mitsubishi Ecodan F8 error
Better than an early Windows/DOS error 'Faulty keyboard...
By JamesPa , 20 hours ago
-
I can now, I done an automation in Home Assist...
By DREI , 20 hours ago
-
RE: Bosch CS5800i 5kW - Experience So Far
What a difference a pump makes. We don't have OpenEne...
By Steelbadger , 20 hours ago
-
RE: Inventor (Midea) Heat Pump short cycling advice
I installed the 80L tank (volumizer) things got better ...
By immunity , 1 day ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@papahuhu at the end of the day if you are happy with h...
By benson , 2 days ago
-
RE: Can you recommend a Mitsubishi service engineer in the Rochdale area?
@dgclimatecontrol We'll all need annual servicing. How...
By Suzy-shadow , 2 days ago
-
RE: Octopus tariffs - a quick comparison
Does indeed need checking, @tim441. Neither Homely ...
By Majordennisbloodnok , 2 days ago
-
RE: How not to install a heat pump
Delighted to hear that the buffer has been replumbed as...
By JamesPa , 2 days ago
-
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@davidnolan22 So far as I can tell from the 'other p...
By JamesPa , 2 days ago
-
RE: 5 Star Service from Havenwise
I keep getting havenwise ads on my Facebook feed, so cl...
By benson , 2 days ago