@soniks FYI we have all brand new pipework and its 28mm, we have the volumiser with the heat element in it and we are getting flow rate of 32 with rad...
We have a 1920's house with a new big extension. We externally insulated and rendered the existing house with 70mm celotex along with high quality mod...
there is a single pipe in which is primary from ASHP and a single return pipe ... primary circuit is on the right as you face the LLH .... secondary i...
First picture shows a symbol not in the manual (as far as I can tell) so wondering if this is the supplementary heating in defrost cycle. The next p...
Important was that box EP001 was wired and it turns off the master valve supporting DHW prioritisation (which it wasnt at first) ... this now works an...
FYI the Grant combined volumiser / low loss header in my system has an immersion. The immersion doesnt connect to EP001 and instead connects directly ...
For the last month I have taken daily meter readings, for my 17kw grant ASHP the least usage being 25th Dec with 37kw/h, the worst being yesterday at ...
As I dont have an electric car and averge less than 30% electric between 00:30 and 6:30 I decided to switch from Economy 7 to single tariff .... now I...
thanks Derek, we do have a LLH my understanding thats to provide hydraulic seperation of primary and secondary circuits and cope with having multiple ...
The TM1 was 45 degrees ... my understanding is this is the max flow temp at -4 degrees for the weather compensation ... I reduced to 40 to try and see...
Hi @derek-m From the original spreadsheet before the reneuvation project started This was based on heating flow temp of 50 degrees due to upstai...
Hi @AllyFish, thanks for the detailed reply, ... I had no idea of the defrost details .... answers follow "17kW ASHP. Who sized it & on what...
- 26 Forums
- 2,104 Topics
- 46.3 K Posts
- 102 Online
- 3,393 Members
Join Us!
Latest Posts
-
RE: BUS Grant: removal of all other fossil fuel heat sources
Hi all, thanks for your help. The installer has confirm...
By Rikiarn , 4 hours ago
-
@pie_eater Try asking the Perplexity AI engine how to t...
By downfield , 15 hours ago
-
RE: No-code, plug-and-play monitoring for your heat pump
Just in case anyone is looking at Planet Atmo- we've ma...
By benson , 15 hours ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
Agree, but you may have a hard time convincing them, as...
By JamesPa , 16 hours ago
-
RE: Seal the Deal: Don't Let Your Heat Pump Leak Energy
Hi - fyi - there's a dead image link in the 'Optimal In...
By seatonian , 1 day ago
-
RE: Ripped Off: How UK Homeowners Are Paying Gas Prices for Wind Energy
@chandykris Horses and beggars…. 😉 Toodles.
By Toodles , 1 day ago
-
RE: Cleaning up after gas meter removed
@agentgeorge Likewise in the loft space; we have 300mm ...
By Toodles , 1 day ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
This particular example is one of the worst I have seen...
By JamesPa , 2 days ago
-
-
RE: Fan running in hot weather ...why?
I wonder if it has some kind of pressure transducer to ...
By ASHP-BOBBA , 2 days ago
-
RE: Cooling with Samsung Gen6 and Flow error
@iaack The system isnt running long enough for any cond...
By EcoBaker , 2 days ago
-
@heacol thanks for confirming we can only hope NAPIT ag...
By Bart , 3 days ago
-
Sorry to hear that @bruce. Sadly I’ve heard from multip...
By Mars , 4 days ago
-
RE: Crystal Ball Time: Communal or even Area Energy Storage?
I am invested in a couple of listed energy storage fund...
By Old_Scientist , 4 days ago
-
RE: Who's your electricity provider and what's your tariff?
That would be my biggest commitment -time to gain great...
By SUNandAIR , 5 days ago
-
RE: Who has a V2G EV installation
As has been discussed on other threads, trying to justi...
By Majordennisbloodnok , 5 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
Thanks @mikeh. Then I will also go back to non smart ta...
By ChandyKris , 5 days ago