Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jul 30, 2026
@derek-m 4051 reads use max 100% 4052 reads 5.0c
@transparent it has a room stat which I’m not sure I should be using, but I need some control over the rooms so Trv on the rads allows that. Generally...
@derek-m I completed the assessment in collaboration with Fernox tech and came to around 280 litres. Requiring a mix to provide protection to -20/25 ....
@derek-m 16 radiators samsung wanted a 46lpm flow rate on 35mm pipe and seem to be supporting the installer by diluting this down to 36lpm on 28mm pip...
I guess tomorrow I need, or they need to decide if they charge it with antifreeze with such a low flow rate and find it shuts down on low flow. The pu...
@jamespa samsung want heaters installed if antifreeze valves are fitted and then of course corrosion inhibitor, but I read up on frost valves and anti...
@jamespa I wouldn’t if it will run without low flow errors
@derek-m I hear what you guys are saying however at a start up of 30.8lpm the system is close to a shut down on low flow which it was doing at 29lpm b...
@transparent it’s not going well, it threw up low flow at start up then went up to 36lpm but now it’s running at 31.8. I went around when they left an...
@transparent well heating guys left for the day and I have 36lpm but antifreeze tomorrow and not sure how much we lose. got rid of manual flow gauge...
@transparent into the realms of witchcraft now. Perhaps two meters then one for house and one for Ev charger. Keeps it simple but I guess you are goi...
@transparent I think they may have only used one of the phases to avoid changing the meter. When I get an EV charger perhaps they might change it the...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 3,427 Online
- 7,222 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Renewables & Heat Pumps in the News
@temperature_gradient There is a good summary of the...
By Rob of York , 9 hours ago
-
RE: Heat Geek installations: share your experiences
@batpred I have a 400% Combined Minimum Performance gu...
By L8Again , 10 hours ago
-
RE: DIY powerflushing tutorial
The problem is that while inhibitors inhibit metal corr...
By Pirate Rich , 12 hours ago
-
RE: How Can I Prove Coal Was My Main Heating Source Without Receipts?
@etchedpixels thank you for the advice paid cash all...
By Chilli304 , 20 hours ago
-
RE: Why don't people choose heat pumps?
Savings you need to consider versus the investment valu...
By EtchedPixels , 1 day ago
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders An interesting conversation to have ...
By Rob of York , 2 days ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
Yes, in my case, the ISP hub is permanently there, they...
By Batpred , 2 days ago
-
RE: Electricity price predictions
@rob-of-york sounds like a term that Heidegger would...
By Papahuhu , 2 days ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 2 days ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 2 days ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 2 days ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 3 days ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 4 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 5 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 5 days ago