Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 16, 2026
@johnnyb So I think what might be happening is at the very low flow temperature you are trying to use, you cannot get the UFH to release enough energy...
@dunlorn @mike-h I’ll try and get the original post where this was stated as an excerpt was passed to me. unfortunately I don’t find that the Sa...
Hi @johnnyb I have the same heat pump as you but use radiators not UFH. You should be able to run the UFH on a lower flow temperature than radiator...
@dinhp Ive just come across some info that improves your SCOP. I was dividing your Generation kWh / Usage kWh to get COP, but it appears Samsung hav...
@pressure Well mine was a new installation in this house, but if upgrading I would definitely install anti frost valves if you are using antifreeze so...
Couldnt you just replace the old Heat Pump unit, leaving everything else as it is? My 5kW Samsung cost just over 2K last year and its simple to switch...
I remember watching a heat geek video about the effects of unheated rooms and how it would impinge on efficiency as the flow temperature in other room...
@jancold yes it’s fine to oversize them, you can just limit their output as required with the valves. It gives you some more flexibility as to room...
@robl Thanks, thats interesting 🙂
@sunandair So my take on it would be that having the walls thermal mass inside the insulation layer, would act as a thermal store and be ideal for 24/...
Two other things that greatly effect SCOP but havent been mentioned are the climate where you are living and what you deem to be a comfortable interna...
Its a big house Alan so getting an accurate heat loss will be important. If I were you I would try and go lower than 54C with your boiler during a col...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 2,659 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
I've not given it much/any thought. I did look at the p...
By Old_Scientist , 23 minutes ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 5 hours ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 7 hours ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 7 hours ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 8 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 1 day ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 1 day ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 2 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 3 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 4 days ago