Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 25, 2026
If flow is too low, the heat pump will probably throw a fault. High flow is not a problem for the heat pump, it'll work fine. Higher flow gives lowe...
Oh my, bureaucracy at its finest! Does that imply that the reason why both my PV inverters and heat pump have a 8 pin connector with extremely basic...
In fact inverters with a bit of local energy storage could also do that, if programmed accordingly. Sadly it doesn't seem the current hardware is prog...
I think we're still going to try hydrogen for residential heating on a small scale, then walk it back after a few buildings get launched into low eart...
Hmm I should have explained it better... Problem with these devices: they have only one pipe. Thus they suck in already conditioned air out of the r...
You guys have it easy It's engineering: calories in, calories out. What I had: stone house, built 1732, 50cm thick walls, estimated thermal mass...
I'd say it's up to you to decide between these two behaviors: * Manual balancing valves * For example Caleffi 132 which has a manual valve and flo...
Same here lol The fact the house had been heated for 40 years by a 12kW ground source heat pump could provide a bit of a hint about the actual heat ...
UFH manifolds are horribly expensive usually, except Chinese models. However manifolds for domestic water (or for heating but not UFH) are quite cheap...
Without information about where and how it was measured, this is useless. Don't even know if DC or AC. EBUS has 20VDC between the two wires when idl...
Single phase heat pump inverter drive consists of boost power factor correction, HV DC bus caps, then three phase full bridge inverter driving the mot...
If you have two isolating valves (one on each end of each loop) which you should in order to isolate a loop in case the pipe or the pipe fitting leaks...