Thank you , I will give it a go , so I am looking at the pump returning the flow to the HP . Just to be clear , I would have thought that turbulance...
I think there is control, there is 1, 11,and 111, written on them, but which pump do I slow if its possible CH pump or HP OUTPUT OR return . Toodles y...
It looks like I can fit Modbus to my Gen 5 Heat pump , I have been sent an instruction to change the installion on my Samsung Controller. My questi...
Thats another visit done as the DHW icon was off on the controller/ I felt the lever positions again and the dhw was closed as it sprung back to where...
Is it possible that , before I went up to the loft at that time , I noticed the HW tank symbol was on the controller. I did try to determine that by f...
Heating circulating with 41.9 and 34.6 HP LINE 37.1C and 32.7 Emitters All pumps , two on HP AND O...
So , on the first two photos the Hp is delivering 43-5c and through to Rads its 37.4 2nd two photos its 36.6c to rads its 32 .8c remembering system ...
Attached earlier photos with HP and rads in circulation Black probes being HP Later without , when I came back to house all systems quiet
Yes I do, I have another set, I will place them shortly. Incedently I notice from the sAMSUNG CONTROLLER that the oat side temp outside is 0.6c and...
@jamespa Yes just a bit ! Only hot DHW of significance is a small bath once a day. There are only two of us . Thanks currently seeking info on Mod...
Thank you for your patience and explaining my questions. There is -so much I understand , but may be over thinking , it’s just that my first month wit...
Sorry I don’t understand the graph, and I don’t know how work out COP. What I can tell you are my Settings 2011 is -5c for Scotland 2012 is 15c amb...
- 26 Forums
- 2,406 Topics
- 54.6 K Posts
- 404 Online
- 6,092 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Post-Traumatic Heat Pump Stress Disorder
OK, I see from your other post that this is quite an ol...
By JamesPa , 3 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
No because its NOT connected to the neutral, its connec...
By JamesPa , 51 minutes ago
-
RE: Please help with the settings ecodan
Hi and welcome to the forums.Does your system use a Mit...
By Sheriff Fatman , 1 hour ago
-
RE: New Daikin 11kW Altherma 3M install - is it working as it should?
I forgot to mention: Octopus measured our heat loss at ...
By Toodles , 2 hours ago
-
RE: Considering MLCP (Multi-Layer Composite Pipe) for ASHP
Thanks Mars and thank you for reaching out to so many p...
By iotum , 2 hours ago
-
RE: Air source heat pump roll call – what heat pump brand and model do you have?
Forum Handle: @davec Manufacturer: Peak Energy Mode...
By DaveC , 2 hours ago
-
RE: Rate the quality of your heat pump design and installation
@radwhispererdwhisperereorourkeditor Well, the guy came...
By razz , 2 hours ago
-
RE: Setback savings - fact or fiction?
Given the weather has been relatively stable, the empir...
By Batpred , 3 hours ago
-
RE: Heat pump not reaching flow temperature
@jamespa system design was for 40 degrees FT at -2 degr...
By DaveC , 4 hours ago
-
RE: GSHP WOES! Midland based engineer recommendations?
@editor That is very kind! Thank you so much.
By johnbroome , 4 hours ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@wally Hi I am not sure how large your house is b...
By TechnoGeek , 5 hours ago
-
RE: Predicted Heat Loss & Needs from MCS calcs vs EPC vs actual
I've been thinking along similar lines to @tim441 from ...
By Sheriff Fatman , 6 hours ago
-
Thanks, @technogeek. Good to hear about the accuracy. ...
By Majordennisbloodnok , 6 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
In my case it was a very specific pattern of behaviour ...
By Sheriff Fatman , 7 hours ago
-
RE: Vaillant aroTherm not heating with many faults
@ashp-bobba Yeah I'll give it a go, will check filter...
By Anon67 , 7 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Perhaps the names at the end of the docume...
By Toodles , 7 hours ago
-
RE: Heatpunk Floor plan issues
@jamiejones85 A2A they will design on dynamic heat loss...
By ASHP-BOBBA , 8 hours ago
-
RE: Fan unit Making terrible noise HELP!!
can you post a video looking inside, at and through the...
By ASHP-BOBBA , 8 hours ago
-
RE: Power outages and storms: A surprisingly good DNO experience
Agreed, which is no more nor less than a customer shoul...
By Majordennisbloodnok , 1 day ago