Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 10, 2026
Not great, 5C = 10-15% efficiency loss (much more according to @heacol). TBH I cant understand whats going on in the buffer, its like there is no str...
Maybe mine as well !As in Buffer remove. New sensor in place and so to correct the flow indications between from HP to buffer /Tank there is a diffe...
@arundalep Many Thanks for your thoughts there, I will wait in that case . I have to say I am not going down the solar route or EV but still want a go...
A query and a rEquest sent to Havenwise yesterday has not been answered yet , so I am going to ask if anyone on this forum who has Havenwise do I need...
Sending for more probes , one is dodgy! Its sending me a higher temp on return to LLH than the feed to rads.
Looking like one pair is 1 degree of difference , black indicators and white .5 c. a difference. Will attach This is just a pickle!
@toodles Ok Thanks , meantime I will go to the loft and extract the probesand test them.
Yes Ill do that. Let me pose the question , forgive me if Im wrong but if a pump is delivering into a tank and the outlet is at the same level as in...
So stick them all to same heat source and see what they say?
12 hours later and after slowing return pump down I get 36.9C and 28.6c HP and for CH 31.5C and 26.5c
So I lowered the return flow and will monitor temperature . In the first 1mn I noticed the the flow return up .2c from 31.1 o .31.3!!
- 26 Forums
- 2,644 Topics
- 61.7 K Posts
- 308 Online
- 7,045 Members
Join Us!
Latest Posts
-
@editor "The interesting bit is that many modern invert...
By Singlespeed , 56 minutes ago
-
RE: Ecodan & MelCloud scheduling
With the prospect of warmer weather this week, I brough...
By downfield , 2 hours ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
I reached out to MCS directly last week on this and her...
By Mars , 3 hours ago
-
Heat Pump Overpromising – What Were You Actually Told Before You Bought?
We're looking into overpromising in the heat pump indus...
By Mars , 3 hours ago
-
RE: Heat Pump Operation in Summer - Valliant 7kW
Yes I use the LG to cool the slabs with underfloor he...
By bobflux , 4 hours ago
-
Mentally you have to separate the ac side and the DC si...
By JamesPa , 17 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
My heating developed a really severe case of noise and ...
By JamesPa , 19 hours ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@l2jad I was just thinking all things being equal. Our ...
By AndrewJ , 1 day ago
-
RE: Heat Pump Manufacturers Recommending Buffer Tanks
Hopefully the ambient temperature sensor drives a weath...
By JamesPa , 2 days ago
-
RE: How many people are happy with their ASHP and do you believe them?
Im looking into these and my figures. The think that I...
By JamesPa , 2 days ago
-
Hi, Does anybody have experience with Heat Geek insta...
By sttpd1917 , 2 days ago
-
I will soon be struggling. Admittedly it is the summer,...
By Batpred , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
Not known yet. I've asked a local Councillor to follo...
By Transparent , 3 days ago
-
Hard to tell but I think I have placed the arrow on wha...
By ASHP-BOBBA , 3 days ago