Last seen: Sep 4, 2025
assuming everything is vaillant, (you have used obscure nomenclature) the the rads should be compensated not fixed. I suspect you are in instal...
@luke pumps use less than 100w, many as low as 5w..they all are speed variable, so look on the pumps. in the first best world you wouldn’...
@hughf the truth is we need a whole new trade called to support the technology.. Why Liz Truss and Kwartang don’t jump on that I have no idea!
@hughf all this exists on viessmann controllers and vaillant, have a look at the installation manuals. Peak load pricing is not unique to the U.K., it...
@derek-m vaillant controls already are self adapting…probably mitsubishi and viessmann… Just because they aren’t in the U.K. doesn’t mean they d...
it’s all designed to be done on the internet remotely..bound up with a service fee for maintenance and supervision.. extending service life to 20-25 y...
@squonk that is indeed the case, but the business model pursued in the U.K. doesn’t encourage that.. There are huge interests in keep installers...
Compensation controls are as sophisticated as they can be as they load match, and cannot be improved, other than the interface. Whats lacking is...
Just keep teasing the curve up... you can also just raise the target room temperature, that lifts the curve. With "none" selected in room control it ...
@squonk going up is as good as going down. make sure you have room control set to on, or extended...other wise it will just work around the outdoor te...
@hughf Is Homely relay switching..or does it speak multiple bus languages?
Set all on off controls to maximum, and raise the heating curve to something more appropriate say 1.4, they come out if the factory at about 0.6 if ...
- 26 Forums
- 2,208 Topics
- 48.7 K Posts
- 55 Online
- 5,868 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time
@old_scientist I realise that the pump running 24/7 is ...
By Mike H , 1 hour ago
-
From Mevagissey to Mousehole, and Portmeon to Polzeath ...
By Transparent , 1 hour ago
-
RE: Daikin 9kW to 8kW Swap Offer from Octopus
Not so. In my case it made the difference between 10.5...
By JamesPa , 2 hours ago
-
@bontwoody, I have to say, the response time here is re...
By Mars , 3 hours ago
-
RE: Renewables & Heat Pumps in the News
It rather depends on what we call 'local area' and 'tot...
By Transparent , 5 hours ago
-
RE: Mitsubishi Ecodan F8 error
Better than an early Windows/DOS error 'Faulty keyboard...
By JamesPa , 6 hours ago
-
I can now, I done an automation in Home Assist...
By DREI , 6 hours ago
-
RE: Bosch CS5800i 5kW - Experience So Far
What a difference a pump makes. We don't have OpenEne...
By Steelbadger , 6 hours ago
-
RE: Inventor (Midea) Heat Pump short cycling advice
I installed the 80L tank (volumizer) things got better ...
By immunity , 11 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@papahuhu at the end of the day if you are happy with h...
By benson , 23 hours ago
-
RE: Can you recommend a Mitsubishi service engineer in the Rochdale area?
@dgclimatecontrol We'll all need annual servicing. How...
By Suzy-shadow , 23 hours ago
-
RE: Octopus tariffs - a quick comparison
Does indeed need checking, @tim441. Neither Homely ...
By Majordennisbloodnok , 24 hours ago
-
RE: How not to install a heat pump
Delighted to hear that the buffer has been replumbed as...
By JamesPa , 1 day ago
-
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@davidnolan22 So far as I can tell from the 'other p...
By JamesPa , 1 day ago
-
RE: 5 Star Service from Havenwise
I keep getting havenwise ads on my Facebook feed, so cl...
By benson , 1 day ago
-
Automation options to maximuse efficiency & ToU tariffs
I started a conversation with ChatGPT. What automation...
By Tim441 , 2 days ago
-
RE: 4 Year Ongoing Heat Pump Battle With Poor Heat Pump Installation
@jamespa Oh, I know some that are good and some not so....
By ASHP-BOBBA , 2 days ago