Last seen: Oct 27, 2023
@hydros What value do you have for [8-06]?
@hydros Are you comfortable accessing Installer settings > Overview field settings?
@hydros I see similar behaviour with my Daikin with rads as well, COP for Feb was 3.6. I wonder what value you are using for Leaving Water Temperature...
@derek-m Thank you for getting back. Does a formula exist to calculate the flow temp for a given outside temp? For example, what would the fl...
Excellent topic @editor - thanks for starting. I wonder can a formula be used to calculate what a specific flow temp will be at an outdoor temp base...
@derek-m Hi Derek, I've been watching it run tonight and it is sometimes running for about 20 minutes and then stops and other times it is starti...
@derek-m Hi Derek, thanks so much again for sharing your expertise. You are quite correct I was confusing the terminology. I have put equ...
@adam-c Hi Adam, Totally agree, the reporting is extremely poor - can only get month to date and previous months. When you're looking at th...
@derek-m Thank you. Delta T is now at the default of 5°C. I have increased the LWT max modulation to 10°C with the same curve set. As you suspect...
@derek-m Thanks so much for getting back to me, really appreciate your time. I've taken the below from the manual; Leaving water temp...
I've been looking through the installer settings and the Delta T is currently set at 10°C The range is 3~10°C, step: 1°C The default is 5°...
Happy New Year everyone 😊 I have been continuing to monitor my system and believe I've managed to make some improvements. I found the setting t...
- 25 Forums
- 1,441 Topics
- 30.2 K Posts
- 23 Online
- 1,225 Members
Join Us!
Latest Posts
-
RE: Jokes and fun posts about heat pumps and renewables
@editor I see you have discovered the Greater Unspotted...
By Toodles , 5 mins ago
-
RE: EV charger installation question – I don't want to bury the cable
So whose electricity is passing through that junction b...
By Transparent , 5 hours ago
-
RE: Are You Getting the Most Out of Your Renewable Energy?
@majordennisbloodnok I'll circulate this post this week...
By Mars , 5 hours ago
-
RE: Effect of Buffer tank or Volumiser
Apologies for re-introducing this topic. I was persuade...
By DavidAlgarve , 5 hours ago
-
RE: ASHP Commissioning: What Questions Should I Ask the Installer?
@derek-m thanks - will look out for the point regarding...
By Declan90 , 16 hours ago
-
RE: Noise problems with newly installed Samsung 8kW ASHP
@editor @kenbone Thanks, I would be very interested ...
By Elton , 17 hours ago
-
RE: No-code, plug-and-play monitoring for your heat pump
This is all a bit too frequentist for my liking. The pr...
By scrchngwsl , 17 hours ago
-
RE: Are Octopuses Slowing Consumer Adoption of Heat Pumps?
@ivanopinion I stumbled across this thread Performance ...
By GunboatDiplomat , 18 hours ago
-
Relax with 4K drone footage of lawn mowing to a smooth Motown tune
Sending out some chilled weekend vibes to everyone. Lis...
By Mars , 1 day ago
-
RE: Incorrect Billing of Customers with a Smart Meter
The starting point of that discussion on Camelot-Forum ...
By Transparent , 1 day ago
-
Share Your Experiences with Heat Pump Manufacturer Support
Have you ever reached out to your air source heat pump ...
By Mars , 2 days ago
-
RE: Is this a bad installation and is there something wrong with my Samsung heat pump?
@ant87 thanks for that.
By David999 , 2 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
I might change my mind again, but I'm currently unlikel...
By IvanOpinion , 2 days ago
-
RE: Samsung ASHP scheduling help
@elgreco69 worth reading the GitHub here as that will a...
By morh , 3 days ago
-
RE: ASHP sizing - value of Heat Transfer Coefficient
@toodles Thanks for the explanation I get it now as I h...
By Jancold , 3 days ago
-
RE: Questions about yearly heat pump maintenance
For the installer, I believe servicing and maintenance ...
By Majordennisbloodnok , 3 days ago
-
RE: Rate the quality of your heat pump design and installation
@retrorich It is very worrying that any of this should ...
By Toodles , 3 days ago
-
RE: Spacing for roof fixing bolts ?
There is another consideration...but alas this doesn't ...
By Transparent , 3 days ago
-
RE: Air source heat pumps and noise
Yes, but when they go wrong things get really sticky. D...
By Majordennisbloodnok , 3 days ago
-
RE: Tell us about your Solar (PV) setup
Now, I know that this may be a little simplistic and pe...
By Toodles , 4 days ago
Heat Pump Humour
Latest Topics
-
Spacing for roof fixing bolts ?
By heat-pump-newbie 6 days ago
-
ASHP sizing - value of Heat Transfer Coefficient
By jamesw 6 days ago
-
Incorrect Billing of Customers with a Smart Meter
By KoRWraith 1 week ago
-
Home energy storage & battery register
By Mars 1 week ago