Activity
 
Notifications
Clear all
william1066
@william1066
Member
Reputable Member
Joined: Jan 5, 2023
Last seen: Feb 13, 2024
Topics: 0 / Replies: 206
Reply
RE: Connecting to Midea MSmartHome using a PC

I suspect a number of them probably also use sqlite internally. Not that should worry you, there are apparently over 1 trillion deployments of sqlite...

2 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

I don't want to diminish the pain of loosing stuff, I have been there before caused by a massive pulse of static that jumped from my finger onto the m...

2 years ago
Reply
RE: Army Housing- Ecodan with UFH efficiency?

An interesting question, and I am sure there will be many opinions on this one, certainly one I would like to get to the bottom of. My current view...

2 years ago
Reply
RE: Heat pump delta T too low - 2c

I am still trying to get my head around this. There is no deltaT parameter in the carnot equation so what specific factors make a dT of 8 degC optima...

2 years ago
Reply
RE: Help me understand what's happening with my Ecodan!

Thanks Derek, I have probes in the floor, not yet connected, I might bring them into the equation, and will report back.

2 years ago
Reply
RE: Water cylinder for heat pump outside the house

Yes [for hot water / not sure if it was hot water & heat pump], the build and installation video is on YouTube [somewhere]. Tried to find it but ...

2 years ago
Reply
RE: Connecting to Midea MSmartHome using a PC

Yes, so at the point my heating is fully controlled by HA, then I will have to put in a second (non prod) environment, for sure. Right now I only upg...

2 years ago
Reply
RE: Vaillant Arotherm monobloc error f.788 - ASHP is not working!

I think this is outside < 3C AND RWT < 25C - can't test today, had to put the heating on before the RWT got to 10C. There is also a recommended...

2 years ago
Reply
RE: Vaillant Arotherm monobloc error f.788 - ASHP is not working!

It is actually mentioned in a Samsung manual [ the 3 degC trigger] The heating is still off right now, and no triggers since outside temp went above ...

2 years ago
Reply
RE: Heat pump delta T too low - 2c

ebay, is where I source the stuff difficult to get or expensive in UK.

2 years ago
Reply
RE: Ecodan circulation pump

I agree that without evidence suggesting otherwise, this is probably the way to go. But this could be a moot point ... ... and likely depends on ot...

2 years ago
Reply
RE: Vaillant Arotherm monobloc error f.788 - ASHP is not working!

@iancalderbank Thanks for that. That also probably explains the "warming cycles" the pump does on it's own using heat from the DHW when outside tempe...

2 years ago
Page 8 / 18
Share:

Join Us!

Trusted Installers

Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.

✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available

👉 Find your installer now!

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security