Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 19, 2026
Hi @lostandconfused - you're in luck.And you're quite right to do some research here for yourself. This issue is currently being discussed in the mo...
Indeed. There are thousands of houses which have substandard electricity supplies! Fault designations for electricity supplies to premises are cover...
Whether the outer metallic braid of the mains incomer is covered by an insulated layer (Polyethylene or Bitumen), it remains the case that the actual ...
I foresee a new business opportunity. I can start a new company to survey rental homes and replace old light-fittings with an LED unit at £5000 each...
The usual type of underground cable with a metal 'outer' is Steel Wire Armoured.This has an external Polyethylene (or XPLE) layer outside of the steel...
I too think that the Solis earthing diagram is confusing. As I see it the situation is this... We commonly have circuits which are protected by an...
I think their response is genuine, and becoming increasingly common amongst DNOs...... with the possible exception of UKPN in SE England. DNO's also...
That might be the case. But I think we'd need a link to such an instruction before we can follow that up. I have provided an additional earth for ...
My apologies @jamespa - I read what you'd posted here and had assumed that you were querying the designation of TN-S on the certificate, and the ...
@papahuhu the build up of ICE is a widespread problem.There are consumers complaining from New York to Minnesota and Chicago. Greenlanders are equal...
No. That's uncommon. It goes back to the days when homes had a separate off-peak meter. As I wrote below my diagram, a separate isolat...
- 27 Forums
- 2,795 Topics
- 66.1 K Posts
- 3,419 Online
- 7,198 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Renewables & Heat Pumps in the News
The irony is there's already an established internation...
By Temperature_Gradient , 35 minutes ago
-
First you need to know how much thermal energy you'll n...
By bobflux , 11 hours ago
-
RE: How quickly would you want/expect heat recovery to take from setback?
@toodles Ah, that makes sense. Your using the TRV bo...
By Singlespeed , 11 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
Come for the low-carbon homes. Stay for George Clarke’s...
By Mars , 2 days ago
-
RE: Octopus Cosy 12 Heat Pump Regret: Incredibly Loud, Poor Heating & Constant Hum - Help!
@razz, as we head into the heating season, I just wante...
By Mars , 2 days ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Not quite, regular A2W heat-pumps need a load of extra ...
By Temperature_Gradient , 3 days ago
-
RE: Heat Geek installations: share your experiences
one thing i learnt from reading people’s comments and e...
By Batpred , 3 days ago
-
RE: Cooling/heating with one unit
"The way we use A2A on a cheap overnight EV tariff is t...
By mrkfm , 4 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
We have ‘signed on the dotted line’ today for a Panason...
By Toodles , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
...or it was there and was lost thanks to laziness and ...
By Majordennisbloodnok , 4 days ago
-
Bufferless design & control of Chinese air to water monoblock hybrid heat pump in Alberta, Canada
This post is about how I successfully configured a buff...
By Tony.Stolz , 4 days ago
-
The installer visited yesterday and suggested the noise...
By JamesChatz , 4 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Your house sounds a lot like mine. 2 surveyors each sp...
By JamesPa , 4 days ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
Thats true only if you do the wrong experiment. Done c...
By JamesPa , 4 days ago