Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 13, 2026
OK, will do.I already have the right contacts in local government to make that approach to the area fire authority. On this evening's BBC TV news I ...
I'm disappointed if that's the case. The fitting of red/yellow rotary switches has been a requirement for houses with renewable generation/storage f...
Rotary switches, and their use by the Fire Brigade Well that's no good in a house that not only has storage batteries, but also a battery control...
Erm... that CT clamp is an input to the MP 3000-SE (Sofar's battery storage controller) rather than the pre-existing PV inverter.According to the manu...
At a nominal 50v battery voltage, you would expect a 5kW inverter to draw 100A max.But that assumes the current is steady. In reality, most loads will...
I too don't like the look of that breaker on the Battery wires. We discussed adequately-sized DC breakers earlier on this topic. You can buy them on e...
Having seen the photos, I too have a plethora of questions! Why is the red/yellow "emergency breaker" placed so high up and to the right?This is w...
I agree with @chickenbig that we need more information on what's connected to the underside of the 3000-SE unit. Another photo perhaps? There also a...
Simply swapping around CT clamps doesn't appeal to me as a logical approach! Assuming that your solar installation and its grid-tied inverter preced...
Those last three photos don't show an 8kW shower in use. They show 1.6kW being used within the home, which is coincidentally matched by the electric...
There's got to be a joke in there somewhere @morgan, but I can't work out if Givenergy is the punchline 🤨 ... alternatively, start a new topic with...
Thanks @misterb. I usually reduce the resolution of a photo to about 800 pixels horizontally before uploading to this forum.Do you have an image edito...
- 27 Forums
- 2,767 Topics
- 65.1 K Posts
- 904 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Siting of the external sensor on a heatpump
Of course had the heat source been a heat pump it would...
By JamesPa , 1 hour ago
-
Never assume, it makes an ass of u and me! OK, tha...
By JamesPa , 2 hours ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 4 hours ago
-
RE: Is it the house or the equipment?
@springswood We have two Daikin single split A2A syst...
By Rob of York , 4 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
You should (almost) always reject having a buffer, by w...
By JamesPa , 1 day ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 1 day ago
-
No, but the heat pump must be capable of delivering a S...
By JamesPa , 2 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 2 days ago
-
RE: Vaillant Arotherm Plus 7KW need a service on it
booked it with Vaillant. will use them until i can find...
By AdamK , 2 days ago
-
RE: Adventures in heat loss calculations
I have seen it stated that the declared calorific value...
By JamesPa , 2 days ago
-
RE: Two heating zones to one zone
@transparent Many thanks. The garage is fairly well ...
By Profzarkov , 3 days ago
-
RE: Vaillant Aurotherm - Heater Wire Position
Ah, good point. I need to check if this was installed i...
By Batpred , 4 days ago
-
@batpred thanks for getting a copy. Appreciate the supp...
By Mars , 4 days ago