Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Illustrious Member
Joined: Jan 20, 2022
Last seen: Aug 6, 2026
Topics: 16 / Replies: 3335
Reply
RE: A question about voltage, batteries and battery operated tools

As this is on an open forum, can I make a response which even more simple?! 1. Each power tool has a voltage at which it must operate.You must m...

3 years ago
Forum
DIY
Reply
RE: New Tariff: Octopus Flux

Thanks for that information @howardp99 Remember that you must first exhaust both stages of a complaint against an energy supplier before the Ombudsm...

3 years ago
Reply
RE: A question about voltage, batteries and battery operated tools

Equally you must use the right charger for your power-tool battery. There are some chargers which can detect the chemistry and voltage of a battery ...

3 years ago
Forum
DIY
Reply
RE: Removing a Meter

No. The substation is where the voltage drops from 11kV to 440/230.In your case that transformer is 35/1198 and it's on a pole next to your house! I...

3 years ago
Reply
RE: Removing a Meter

It is typical of the energy sector that they use official terminology to describe something, but that the naming isn't well founded on either the unde...

3 years ago
Reply
RE: Removing a Meter

Service Fuses and their conditions are covered in the Meter Operators Code of Practice Agreement.I strongly suggest that you download a copy of the ol...

3 years ago
Reply
RE: Removing a Meter

Thanks @rusty. There's lots of correct detail in what you write, which indicates that you have been talking to the right people. However, it is usua...

3 years ago
Reply
RE: New member - advice sought

Erm... what's the return water temperature for your boiler in its present situation? If it's above 45degC, then your HP won't be able to add anythin...

3 years ago
Reply
RE: 1.000.000 watt hours in a box from Sunsynk ...

These look to me like they are 5kWh rack-mount boxes.So they'll probably have 100Ah cells inside. I wonder why they've decided to start from a relat...

3 years ago
Reply
RE: New member - advice sought

Hi @jvs197 and welcome! My first observation is that your 8.5kW ASHP is already oversized for your sumptuously-insulated house.So your system design...

3 years ago
Reply
RE: Removing a Meter

Your meter falls within the responsibility of your Energy Supplier, whereas the 100A Service Fuse belongs to your DNO.So you'll need to seek advice on...

3 years ago
Reply
RE: Say hello and introduce yourself

Not a photo which screams out "well insulated pipework" @gc61 🤔 Equally, whilst Viessmann could use your third photo for advertising purposes, on...