Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 26, 2026
The folks over at diysolarforum.com are getting quotes for $1300-1800 (delivered, variously to US, EU, etc) for ~10kWh of LiFePO4 cells from China, de...
I'm not aware of smart TRVs with external temp sensors, but one possibly useful thing is that UFH setups typically have the valve and the temperature ...
I think what you're talking about are Fan Coil Units or FCUs. They're basically a pipe with metal fins to transfer the heat, with a fan to blow air t...
I'm not sure that difference is 'set', but it's essentially the properties of your heat emitters (radiators, UFH etc) and water cylinder. For exampl...
Oops, missed the edit window. It's section 8.4 on page 120 (External Heat Source) not 8.3 (electric backup heater) - it appears you can have both and ...
For Grant the heatpumps are made by Chofu who provide a much more detailed manual. See section 8.3, page 111 onwards: In particular, 8.3.2 describe...
The interviewer sounds like she wants to be Jeremy Paxman, interrupting and not letting the interviewees speak. But that seems to be her style - list...
Hi Cally We’ve had a 13kW Grant installed about a month now, and it was really noisy to begin with. It came from the pipes, although the outdoor...
Question from me: What are the risks of oversizing an ASHP, and are there ways they can be mitigated? For example, might minimum flow rate be a prob...
I did look at RED - Freedom Heatpumps have some videos on them. I'm a bit wary about this 'designed for the UK climate' thing: I've seen that slogan...
I came across this video: This is the perspective of, shall we call them, 'Big Boiler'. They take the position that they can build hydrogen boil...
- 27 Forums
- 2,753 Topics
- 64.7 K Posts
- 1,602 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Surface mount or bury primaries for heat pump installation?
The installation is almost done! I've written up two ...
By tomasmcguinness , 5 seconds ago
-
RE: Adventures in heat loss calculations
As others have said, well done, and thank you for posti...
By cathodeRay , 5 minutes ago
-
RE: Glass lined Cylinder for private water supply
This has turned into a fascinating little rabbit hole. ...
By Mars , 9 hours ago
-
RE: Switch suitable to change between two inverter CT's
Last winter my battery ,32KWh, could run the house com...
By Jancold , 10 hours ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@rob-of-york Thank you for that, whilst familiar with t...
By kilgorexv , 10 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Agree with Major. And even if I was very happy with ...
By Batpred , 11 hours ago
-
RE: Is the "divide by 2900" rule still valid?
There is another estimator that you could use, a formul...
By Rob of York , 14 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 4 days ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 4 days ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 4 days ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 4 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 5 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 5 days ago